点击查看大图
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

User's manual of MPTS-810Hc PT paralleling and voltage protection DeviceV1.03

大小:
435KB
类型:
PDF文档
内容:
共24页
最后更新于:2019年05月21日
44
纠错
全文文本
Zhuhai Wanlida Electrical Automation Co., Ltd. http://www.zhwld.com User’s manual of MPTS-810Hc PT paralleling and voltage protection device Prepared by: Zhu Yanan Proofed by: Li Changwen Approved by: Lin Cunli Document No.: WLD [K]-JY-309-2018 Version No.: V1.03.01 Date of publication: June, 2018 Copyright: Zhuhai Wanlida Electrical Automation Co., Ltd. Note: Our Company reserves the right to modify this manual. For any inconsistency between the product and this manual, please contact us for relevant services. Technical support hotline: 0756-3395398 Fax: 0756-3395111 Foreword F o r e w o r d 1. Model description MPTS-810Hc is PT paralleling and voltage protection device. 2. Standards referenced General specification for static protection, security and automatic equipment, DL 478-2001 Technical code for relaying protection and security automatic equipment GB/T 14285-2006 Protective relay and automatic equipment design rules of power equipment GB50062-92 Transformer substation correspondence network and system DL/T 860 Intelligent substation technology norms Q/GDW 383 -2009 Intelligent substation relay protection technical specifications Q/GDW_441-2010 IEC61850 engineering application model Q/GDW 396-2010 3. Caution  Negative sequence voltage involved in this series of protection is combined with phase voltage.  The appearance should be inspected before power is applied, to ensure that the panel is OK without scratch, the screws are tightened, the device is grounded firmly, all screws of plug-ins are tightened and in good contact.  When power is applied, the “Run” indicator on the panel should flash, protection and measuring data are displayed on the lcd in cycle.  It is prohibited to plug or unplug the plug-ins, in order to avoid damage to the device.  It is prohibited to do digital output test when the device is running with primary equipments. 2 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 1. Product description 1.1 Scope of application The MPTS-810Hc PT parallelling and voltage protection device applies to different voltage ratings. The device can perform parallelling operations according to the operating condition of PT and the bus. 1.2 Function and specification 1.2.1 Protective function  PT parallelling function(Remote/Local)  Over-voltage protection of Bus I and II  Low-voltage protection of Bus I and II  Alarm of zero sequence voltage of Bus I and II  Alarm of PT failure of Bus I and II 1.2.2 Auxiliary function  Phase display  Self-checking fault alarm of device  Remote calling and modification of protection’s settings  One way (or two ways) programmable output of 4~20mA  Network print  Virtual correspondent node remote test 1.2.3 Monitoring function  Electric quantity measuring(remote measuring): Voltage of both bus, negative sequence voltage, zero-sequence voltage of both bus and frequency of both bus.  Remote binary quantity: the device has 20-way binary input. 1.2.4 Communication capability  With industrial Ethernet port and standard RS485 multipoint communication port. Supports ModBus、IEC-60870-5-103(RS485 communication mode)、IEC-61850-5-104(Industrial Ethernet communication mode) standard communication protocol and a new generation of substation’s communication standard IEC 61850.  Supports single and dual network communication, it is fully qualified for network redundancy and backup 1.2.5 GPS clock synchronization function  The device is able to receive GPS clock second synchronization or IRIG-B through RS485 differential voltage, and it can be done with monitoring system to accomplish GPS precise clock synchronization or Ethernet-based SNTP synchronization. 1.2.6 Device specifications  32-bit POWERPC microprocessor 3 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018  Real-time multi-task operating system and C++ program techniques, realizing online programming  320*240 LCD display, easy for inspection  One or two ways 4~20mA DC quantity output, which can be set flexibly as any corresponding electric quantity (such as current, voltage, power, etc.)  Having the electric energy quality analysis function and perfect harmonic analysis function  Support network printing function, include two ways: real-time print and artificial print  Support virtual correspondent node remote test, including remote communication to correspondent node, remote measure to correspondent node, event to correspondent node, can online testing, it is convenient for debugger to debug the device on-site.  Excellent hardware interchangeability, user maintenance is easily and it reduced quantity of spare parts  Protection output relays can be configured flexibly for user convenience  Using a 6U, 19/3” standard enclosure in a rear plug-in structure. the device can be installed in site on a switchboard or combined in a centralized manner 1.2.7 Main technical specifications  Rated data Power supply: DC/AC 86~265V Operating voltage: DC 220V or DC 110V AC voltage: 100/ 3 V or 100V  Power consumption DC circuit: <10W (normal operation); <15W (protection operation) AC voltage circuit: <0.5VA/phase  Overload capability AC voltage circuit: 1.2Un, continuous operation  Range and error of setting value  Maximum range of setting value: Voltage element: 1V~120V Frequency: 45.00Hz~55.00Hz Timing element: 0.00S~100.00S  Error of setting value: Current and voltage setting value: ≤±3% of setting value Frequency setting value: ≤±0.02Hz  Whole-group operation time (including relay’s intrinsic time): Intrinsic operating time of voltage protection: not greater than 40ms.  Measuring accuracy AC voltage: Class 0.2 Frequency: ≤±0.02Hz SOE resolution: ≤2ms 4 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 4~20mA DC quantity output: ≤±1%  Capacity of trip/closing output contact Can be connected to DC 250V, 8A for prolonged periods.  Environmental conditions   Ambient temperature:   Operating:-20℃~+55℃. Storage:-25℃~+70℃, rainproof and snow-proof rooms with relative humidity not greater than 80%, ambient air free of acid, alkaline or other corrosive and explosive gas. No excitation quality is applied at the limits, the device shall not have any irreversible change. After temperature restoration, the device shall operate properly. Relative humidity: The average relative humidity of the most humid month shall not be greater than 90%, the average minimum temperature of this month not lower than 25℃ and there shall be no surface condensation. At the highest temperature of +40℃, the average maximum humidity shall not exceed 50%. Atmospheric pressure: 80kPa~110kPa (below relative altitude of 2KM) 1.2.8 Hardware structure The device uses a 6U, 19/3” standard enclosure, with aluminum alloy casing and installed by overall embedding. The display panel is mounted in the front, and the other plug-in modules are rear mounted. From the rear view, I/O, the power, CPU and AC plug-in modules are from the left to the right.  External dimensions and boring diagram Structural and dimensional diagram Boring diagram for installation 5 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Devices fabricated on-screen steps: first release on-screen stents unfastening screws, remove the stents. Install the device on the screen from the front and push until close to the fixed plate. Install the stent 2, and then stent 1, and then use fastening screw to insertion hole from rear of stent1, and then screwed into stent 2 and tighten screw. The stents from up and down are installed in the same way. Use grounding screws to connect grounding line. 2. Function of device 2.1 PT parallelling function For 2 buses or a single bus with different operating sections, when any PT group on the 2 bus sections has a fault and must be stopped, PT Parallel can be carried out manually or remotely through this device. The device supports PT manual paralleling and remote paralleling. Figure 2-1 Parallel logical diagram 6 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 PT Manual Parallel/Split: When the SA (rotary switch) is located in the position of Manual Parallel, +WC is tied to A15 (PT Manual Parallel input), PT Parallel output will be closed. When the SA (rotary switch) is located in the position of Manual Split, +WC is tied to A16(PT Manual Split input), PT Parallel output will be opened. This function is controlled by hardware, not software. It also has self- maintain function. PT Remote Parallel/Split: When the SA (rotary switch) is located in the position of Remote Control, the input of Remote/Local is on, then the device receives the order of remote Parallel, YHJ relay will be drived to closed , +WC is tied to A15 (PT Manual Parallel input), PT Parallel output will be closed. When the device receives the order of remote Split, YTJ relay will be drived to closed , +WC is tied to A16 (PT Manual Split input), PT Parallel output will be opened. Note: when Remote operation, the -KM must be input -DC 220V voltage, Remote Parallel output is tied to A15 and +DC220 in series, Remote Split output is tied to A16 and +DC220 in series. 2.2 Over-voltage protection function The device can monitor the voltage of 2 bus sections. When the maximum of line voltage of a bus section is higher than the over-voltage setting value and the delay is reached, the over-voltage protection will operate. The over-voltage operations of the 2 bus sections operate on different outputs. Figure 2-2 Over-voltage protection logical diagram 2.3 Low-voltage protection function The device can monitor the voltage of 2 bus sections. If any voltage of the 2 bus sections is normal,When the minimum line voltage of a bus section is higher than the low reverting voltage and the maximum line voltage of that bus is lower than the low voltage setting value and higher than loss-of-voltage setting, and the delay is reached, the low voltage protection will operate. The low voltage operations of the 2 bus sections operate on different outputs. Figure 2-3 Low voltage protection logical diagram 7 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 2.4 Zero sequence voltage alarm function The device can monitor the zero sequence voltage of 2 bus sections. When single-phase grounding occurs in a bus section, as its zero sequence voltage is greater than the setting value and the delay is reached, a zero sequence alarm signal will be given. Figure 2-4 Zero sequence over-voltage protection logical diagram 2.5 PT failure alarm function The device can monitor PT failure of 2 bus sections. It has the following criterion for any period of busbar PT. When PT failure protection is putting on, negative sequence voltage U2>8V, and the delay 10s is reached, it will be considered PT failure. When PT failure protection is putting on, negative sequence voltage U2<8V, and the delay 3s is reached, it will be alarmed as PT failure. 2.6 Display In normal operation, the LCD screen displays the protection line voltages on primary side of 2 sections Uab1, Ubc1, Uca1,Uab2, Ubc2, Uca2, opening triangle voltage of 2 sections U01,U02,and the frequency of 2 sections F1, F2 and communication address alternatively in turn. The high brightness LED displays the maximum voltage of 2 sections (1b, 2b). 2.7 Network print Device supports network printing function, can print remote control information, soe information and the setting parameter list. The printer IP address must been set rightly on the device(the network segment of printer must be as same as that of device IP addresses), then connect a printer, put on "real-time report print ", it can print the current remote control information or soe information when device is connected to the background(including remote communication shift, protection action), and can print the current soe information when device is not connected to the background. In addition, when press the "ok" button in the "print report" or "print setting value" menu, it can print the all setting parameter or the all report information, including action value. 2.8 Virtual correspondent node remote test The function is used to complete the communication node remote test of the device, do not need to access the actual analog electric quantity or the input quantity. Specific operation as follows, connect to the background, In the remote test menu, operate the “virtual input test”, the “virtual measure test” and the “virtual SOE test” menu in the “remote test” menu, press the "OK" button after the modification of 8 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 various settings, then by observing the background pop-up warning window or the change of the corresponding value, to determine whether the device communication node is right. It is convenient for debugger to debug the device on-site. 2.9 GPS clock synchronization The GPS clock synchronization signal is input as rs485 differential voltage, the device is able to receive GPS clock second synchronization. If there is GPS signal, there will be flashing on the bottom of cycle menu. Otherwise won’t. The principle of GPS clock synchronization: The second pulse or minute pulse act with the monitoring system, the time base with second precision is sent by monitoring system, when the GPS second differential signal arrives, the time base is unified and the milliseconds are cleared. The device is able to receive GPS clock second synchronization or IRIG-B through RS485 differential voltage, and it can be done with monitoring system to accomplish GPS precise clock synchronization or Ethernet-based SNTP synchronization. 2.10 Overhaul status When the device put into overhaul plate, remote sign, remote measure can uploading background computer. But the device can’t remote control by background computer. The SOE event、Alarm event、Trip event, etc also can’t uploading background computer. 3. Setting of parameters and setting values of the device 3.1 System parameters Parameter Range Description Settings of setting value zone number(Setting Zone No.) Setting value zone 0-7 Set step:1(factory default 0) number(Setting Zone No.) Communication settings(Comm. Setting) Set step :1 (factory default 1) NET Protocol 0-2 (0-Quit;1-IEC104; 2-IEC61850) Set step :1 (factory default 0) RS485 Protocol 0-2 (0-Quit;1-IEC103; 2-Modbus) RS485 address(RS485 1-99 Set step:1(factory default 1) Address) RS485 baud rate(RS485 Set step:1(factory default 2)0:2.4KB;1:4.8KB; 0-5 Baudrate) 2:9.6KB;3:19.2KB;4:38.4KB;5:115.2KB; IP address(IP Address) It has four One section set step:1(factory default 192.168.0.253) SNTP Address (SNTP sections. The One section set step:1(factory default 192.168.0.254) Address) range of every 9 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Parameter Range Description KW default value(KW section is One section set step:1(factory default 12.8.6.1) Default) 0-255 Printer IP address(Printer One section set step:1(factory default 192.168.0.134) IP) Coefficient of transformer Bus 1 PT Ratio (Bus 1 1-1500 Set step :1(factory default 1) PT transformation ratio) Bus 2 PT Ratio (Bus 2 1-1500 Set step :1(factory default 1) PT transformation ratio) Setting of basic parameters(B. Parameters) V Connection (Voltage 0-1 Set step :1 (factory default 0) 00:YY;01:VV Wiring mode) Remote communication 10-100ms Set step: 1 (factory default 40ms) ack time (input ack time) Real-time print report 0-1 Set step: 1 (factory default 0) 00:exit;01:on on/off(auto print report) D/A channel setting(D/A Setting) Select DA1~2 to output corresponding reference quantities: 0:No D/A output DA1~2 Channel 0-14 1:Ua1,2:Ub1,3:Uc1,4:U01,5:Ua2,6:Ub2,7:Uc2,8:U02,9: Selection Uab1,10:Ubc1,11:Uca1,12:Uab2,13:Ubc2,14:Uca2 Voltage reference quantity: 0-120V corresponding to 4mA-20mA, DA1~2 Adjustment 0.5-1.5 Adjust D/A channel 1~2(4-20mA) parameters Factor Channel factor setting(Channel Coef.) Channel 1-8 0.500-5.000 Set step:0.001(factory default 1.000) 3.2 List of setting values Setting value Range Description Bus1 OverVoltage 1/0 1/0:ON / OFF (factory default OFF) Bus1 Low Voltage 1/0 1/0:ON / OFF (factory default OFF) Bus2 OverVoltage 1/0 1/0:ON / OFF (factory default OFF) Bus2 Low Voltage 1/0 1/0:ON / OFF (factory default OFF) 10 Protection on/off word User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Setting value Range Description Bus1 Ground Alarm On/Off 1/0 1/0:ON / OFF (factory default OFF) (Bus1 GroundAlarm) Bus2 Ground Alarm On/Off 1/0 1/0:ON / OFF (factory default OFF) (Bus2 GroundAlarm) Bus 1 PT Failure On/Off (Bus 1 PT 1/0 1/0:ON / OFF (factory default OFF) Failure) Bus 2 PT Failure On/Off (Bus 2 PT 1/0 1/0:ON / OFF (factory default OFF) Failure) Protection of bus I voltage(Bus 1 V PROT) Setting value of Bus I 90-150V Set step:0.01V(factory default 120V) over-voltage (Over Voltage 1) Setting value of Bus I 10-90V Set step:0.01V(factory default 60V) low-voltage (Low Voltage 1) Setting value of Bus I 5-60V Set step:0.01V(factory default 30V) loss-of-voltage (No Voltage 1) Bus I over-voltage delay 0.1-100s Set step:0.01s(factory default 100s) (Over Voltage 1 T) Bus I low-voltage delay 0.1-100s Set step:0.01s(factory default 100s) (Low Voltage 1 T) Protection of bus II voltage (Bus 2 V PROT) Setting value of Bus II 90-150V Set step:0.01V(factory default 120V) over-voltage (Over Voltage 2) Setting value of Bus II 10-90V Set step:0.01V(factory default 60V) low-voltage (Low Voltage 2) Setting value of Bus II loss-of-voltage (No Voltage 5-60V Set step:0.01V(factory default 30V) 2t) 11 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Setting value Range Description Bus II over-voltage delay 0.1-100s Set step:0.01s(factory default 100s) (Over Voltage 2 T) Bus II low-voltage delay 0.1-100s Set step:0.01s(factory default 100s) (Low Voltage 2 T) Bus I zero sequence voltage protection(Bus 1 Ground) Bus I zero sequence voltage setting value Set step:0.01V(factory default 100V) (ZS Voltage 1 Set) 5-100V Bus I zero sequence delay Set step:0.01s(factory default 100s) (ZS 1 Time) 0.1-100.00s Bus II zero sequence over voltage protection(Bus 2 Ground) Bus II zero sequence voltage setting value 5-100V Set step:0.01V(factory default 30V) (ZS Voltage 2 Set) Bus II zero sequence delay 0.1-100.00s Set step:0.01s(factory default 100s) (ZS 2 Time) 4. Description of binary input, output and analog quantity 4.1 Monitoring of analog quantities Analog quantities can be monitored under the [Protection Data], [Measured Data] and [Pulse Energy] menus in the [Run States] menu, press the “”, “” keys to flip over. The factory precision of the device has been calibrated. The protection current is calibrated at double the rated current and the measuring current at a single rated current. The list is as follows: Analog quantity Analog quantity Test method terminal name Bus I Phase A Terminals D01, D02 voltage for Add 100V, displayed deviation not exceeding 1% protection Ua1 Bus I Phase B Terminals D03, D04 voltage for Add 100V, displayed deviation not exceeding 1% protection Ub1 Bus I Phase C Terminals D05, D06 voltage for Add 100V, displayed deviation not exceeding 1% protection Uc1 Bus I zero Terminals D07, D08 sequence voltage Add 100V, displayed deviation not exceeding 1% U01 12 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Bus I frequency for measurement Add 60V on Ua1 at industrial frequency 50 Hz, f1 displayed error not exceeding ±0.02Hz Bus II Phase A Terminals D09, D10 voltage for Add 100V, displayed deviation not exceeding 1% protection Ua2 Bus II Phase B Terminals D11, D12 voltage for Add 100V, displayed deviation not exceeding 1% protection Ub2 Bus II Phase C Terminals D13, D14 voltage for Add 100V, displayed deviation not exceeding 1% protection Uc2 Bus II zero Terminals D15, D16 sequence voltage Add 100V, displayed deviation not exceeding 1% U02 Bus II frequency for measurement Add 60V on UA2 at industrial frequency 50 Hz, f2 displayed error not exceeding ±0.02Hz 4.2 Monitoring of binary input Binary input can be monitored under the [Binary input] menu in the [Run States] menu, press the “”, “” keys to flip over. Binary input Binary input name Test method terminal B01 Common terminal of binary input - (Should be connected to DC220V or DC110V negative terminal of external power External power supply of 220V or 110V DC supply) can be applied, connect the negative terminal B02 Input 1 to terminal B01, positive terminal to terminal B03 Input 2 B02~B21, in [Binary input] menu in the B04 Input 3 [Run States], the status of binary input can be seen. B05 Input 4 The device also has a 24V DC supply, if B06 Input 5 it is used, terminal B22 can be connected to B07 Input 6 terminal B02~B21, in [Binary input] menu B08 Input 7 in the [Run States], the status of binary input B09 Input 8 can be seen. B10 Input 9 Please note about the binary input voltage B11 Input 10 upon ordering, it is set to DC220V by default. B12 Input 11 B13 Input 12 B14 Input 13 13 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 B15 Input 14 B16 Input 15 B17 Input 16 B18 Input 17 B19 Input 18 B20 Input 19 B21 Overhaul B22 Positive terminal of internal 24V power supply 4.3 Monitoring of binary output Binary output can be monitored under the [Binary output] menu, press the ““, ““ keys to flip over. Binary output terminals Binary output name Test method B23-B24 Trip Signal B23-B25 Alarm Signal A17 -KM A19-A20 PT Parallel Signal A21-A22 Earth Signal Select open and close menu, use “+”, “-” A23-A24 PT Failure key to operate and test the corresponding A25-A26 Bus 1 Abnormal V terminals. A27-A28 Bus 2 Abnormal V Remote Stepout Output A29-A30 (R.S. Output) Remote Parallel Output A31-A32 (R.P. Output) 14 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 5. Operation instructions 5.1 Control panel of device  320*240 matrix LCD (The LCD will go off after a period of absence of keyboard operation. the LCD will be illuminated automatically when any key is pressed or in case of protection trip or alarm.)  Signal indicator: run, communication, trip, alarm, fault (of the device), parallel, remote.  Key pad: , , , , Cancel, -, +, Enter, Revert 5.2 Instructions for use of key pad and LCD display During the device’s normal operation, it will display the primary measuring current、voltage、 power, secondary protective data、measuring data、device address、time and statue (indicating whether reclosure charging is finished) in cycle. Press the “Enter” key to enter the main menu, which is a multi-level tree menu. Press the ““, ““ keys to move the cursor to the desired entry, press the “Enter” key to enter this entry, and press the “Cancel” key to return to the next higher level of screen. If this screen is still a menu, continue to press the ““, ““ key to select the desired entry, press the “Enter” key to enter the next level of screen, and press the “Cancel” key to return to the next higher level of menu. If there is no menu screen, be sure to press the “Cancel” key to return to the next higher level of menu. The main menu is shown at the center of the following figure, with the corresponding submenus on both sides. 15 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 01.Run States -1/5- Main menu 05.Report Dis. -1/4- Protection Data Trip Report Measuring Data 01.Run Status Binary Report Binary Input Event Report Soft Strap 02.Run Parameters Print Report AD Volt.Data 03.Setting View 06.Parameters -1/6- Comm. Setting 04.Setting Value Transformer Coe. B. Parameters 02.Run Param. -1/3-  Setting Zone No. 05. Report Manage D/A Setting Pulse Energy PROT On/Off Clock Setting 06. SYS Parameters Channel Coe. 07.DeviceTest. -1/2- 03.Setting View-1/16- 07.Device Test  Output Test  Bus1 OverVoltage Bus1 Low Voltage 08.PassWord Lamp Test Bus2 OverVoltage ...... 09.Version Info. 08.Password □□□□ 10.Comm Test 04.Setting Value-1/16-  Bus1 OverVoltage PROT AUTO DEV V2.00 Bus1 Low Voltage Type:MPTS-810Hc 10.Comm test Bus2 OverVoltage ID:□□.□□.□□ Input Test ...... CRC:□□□□□□□□ Measure Test Date:20XX-XX-XX SOE Test  Note 1:For the Setting menu, see the description of each device.  Run Status The [Run Status] menu contains 8 submenus, including protection data, measuring data, binary input, soft strap, pulse energy, harmonic data, DC measurement and trip statistics, AD voltage data. It is described as follows: Bus 1 Data ↑ ↓ Ua1 = □□□·□□ V Ub1 = □□□·□□ V Bus I protection PT secondary voltage value Uc1 = □□□·□□ V U01 = □□□·□□ V U21 = □□□·□□ V Bus I zeggive sequence voltage value and frequency F1 = □□□·□□ Hz 16 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Bus 2 Data ↑ ↓ Ua2 = □□□·□□ V Ub2 = □□□·□□ V Bus II protection PT secondary voltage Uc2 = □□□·□□ V U02 = □□□·□□ V Bus II zero voltage value, negative U22 = □□□·□□ V sequence voltage value and frequency F2 = □□□·□□ Hz Binary Input -1/25- Input 1 :□ Input 2 :□ Input 3 :□ Input 4 :□ Input 5 :□ Description varies with model, see corresponding terminal Input 6 :□ diagram for details Input 7 :□ Input 8 :□ Input 9 :□ Input 10 :□ ......  Note: In the standard configurations, the input circuit has the connection to an external 220VDC control power supply. When no DC control power supply or control system is available on site, but a 110VDC control power supply is available, a 110VDC control power supply may be used for direct connection through local hardware adjustment, or the 24V power supply of the device may be used as the input power supply (when the input common terminal is +24V, terminal number: B22, Terminal B01 is kept float). However, this must be specified upon ordering. Soft Strap -1/9- Bus1 OverVoltage Off Bus1 Low Voltage Off Bus2 OverVoltage Off ...... AD Volt. Data -1/2- AD1:□□·□□□V AD Voltage Check AD2:□□·□□□V  Run Parameters In the [Run Parameters] menu includes 3 submenus,including [Settng Zone No.]、[PROT On/Off]、[Clock Setting], The screen Content is as follows:  Setting Zone No. :Range 00~07.  PROT On/Off:The device protect plate can be select in this menu. 17 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 PROT On/Off -1/9- Parameter Modify Bus1 OverVoltage On Off ◇Enter ◆Cancel Press “+”, “-” keys to select the protection function On or Off. The interface will eje ct the window as right chart show when you press the “Enter” key. Move the cursor to t he desired position for modification by pressing the “”, “” keys. Press the “Enter” key to complete setting, and the device will prompt modifying success or not. If the “Cance l” key is pressed, the protect plate status setting will be cancelled and the menu will retur n previous menu.  Clock setting: A battery-back real-time clock is provided in the device, which can perform time adjust remotely via the communication network or in-site time adjust in the [Time Setting] menu. Enter this menu and press the “Enter” key, the clock will stop refreshing and a cursor will Clock setting appear. Move the cursor to the desired position for modification by pressing the “”, “” keys, modify to the desired value with Date:20□□-□□-□□ the “+”, “-” keys. Press the “Enter” key to complete setting. If Time: □□:□□:□□ the “Cancel” key is pressed, the setting will be cancelled and the screen continues to refresh the clock.  Setting View This meun just for query.You can’t modif the value to prevent faulty operation.  Setting Value After entering the password, you can enter the [Setting Value] menu. See the settings description of the protection device for the detailed description.  Report Manage The [Report Manage] menu includes 4 submenus, including trip report, binary report, event report and print report. Event recording includes: device self-check fault, device setting value modification, system parameter modification and setting zone number modification, etc. Trip report can be record for the last 50 events, binary report for 100, event report for 30 at most. Beyond this, the latest report will overwrite the earliest one. Press the “Enter” key to enter the corresponding [To view xx report, please enter report number: 00] menu, and enter any figure within storage volume, press the “Enter” key to display the contents of that report. The screen is as follows: Report No.:□□ ↓ Report No. of this report Year, month, day, hour, minute, second and 20□□-□□-□□ millisecond when it took place □□:□□:□□:□□□ □□□□□□ Press  key to see the specific operation value. Press  and  keys to flip over. Operation values. 18 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Action value view Uab1 = □□□·□□ V Ubc1 = □□□·□□ V Voltage of Bus I Uca1 = □□□·□□ V Uab2 = □□□·□□ V Voltage of Bus II Ubc2 = □□□·□□ V Uca2 = □□□·□□ V U01 = □□□·□□ V Zero sequence voltage, U02 = □□□·□□ V 。。。。。。  System parameters After entering the [SYS Parameters] menu, the correct password is required to enter the [SYS Parameters] menu. It displays the following: Parameters -1/6- Comm. Setting Transforrmer Coe. B. Parameters D/A Setting Channel Coef.  Communication Setting Comm. setting -1/8- NET Protocol □□ 00:Quit; 01:IEC104; 02:IEC61850; RS485 Protocol □□ 00:Quit; 01:IEC103; 02:Modbus; RS485 Address □□ RS485 Baud rate Communication address of device 01~99 □□ 00:2.4KB;01:4.8KB;02:9.6KB;03: IP Address □□□. □□□. □□□. □□□ 19.2KB;04:38.4KB;05:115.2KB SNTP Address □□□. □□□. □□□. □□□ K W Default For Ethernet communication □□□. □□□. □□□. □□□ Printer IP □□□. □□□. □□□. □□□  Transform Coefficient TransformCoe -1/2- Bus1 PT □□□□ Bus2 PT □□□□ Max:1500 Min:0001 19 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 It will prompt maximum value and minimum value of each parameter below the window.  Setting of basic parameters (see the description of the protection device for basic parameters) B.Parameters: -1/11- PT Wiring Mode □□ Setting the PT secondary wiring mode00: Y-Y. 01: V-V ......  D/A setting The device has two 4~20mA outputs. The DA1~DA2 adjustment factor is used to adjust the accuracy of the channel output. The DA1~DA2 channel selection is used to select the corresponding analog quantity channel (see the description of the protection device for specific reference quantities). In the accuracy test, make sure the field ground is in good contact. otherwise the accuracy might be affected.  Pulse energy setting Energy base numbers can be set, including positive active energy, positive reactive energy, negative active energy and negative reactive energy.  Channel Coefficient The device can adjust channel coefficient by this menu to raise Sample size.  Device test After entering the [Device Test] menu, the correct password is required to enter the [Device Test] menu. It’s have two menu include [Output Test] and [Lamp Test].  Output Test Enter [Output Test] menu, It displays the following: Output Test -1/14-  PT Parall Signal Press “Enter” key PT Parall Signal …… On Off Operate All Note: Node:A19,A20 Open Press “Cancel” key (Note: When the test is performed on the 6 protection outputs, the starting relay will be in the “Closed” state automatically. The “+”, “-” keys are used for switching between the “Close/Open” control.)  Lamp Test Lamp Test ◇Light ◆Quench Used for testing Stand or fall of all LED lights.  Password The [Password] menu is used to modify the password for entry into the Settings, System 20 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 parameters and Output Test submenus. The initial password is provided by the factory. The universal password is “1000”. Move the cursor to the desired position for modification by pressing the ““, “” keys, Input password modify to the desired password with the “+”, “-” keys. Press the 0 0 0 0 “Enter” key to enter the new password setting menu as above. Press the “Cancel” key to cancel the setting.  Version information In the main menu, after entering the [Version Info.] menu, the Type, ID, CRC and Date of the software will be displayed. PROT AUTO DEV V2.00 Type:MPTS-810Hc ID:□□.□□.□□ CRC:□□□□□□□□ Date:20XX-XX-XX Note: For a corresponding nonstandard model, the device’s displayed Type does have to be changed.  Comm test When debugger debug the device on-site in the case of no-accessing the actual analog electric quantity or the input quantity, [Comm Test] is used to do the test of the communication node of the device. 21 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Addendum 1: Terminal diagram of the device I/O POW ER CPU A C Input comon A01 B01 point- A02 B02 Remote/Local NET D01 Ua1 Ua1' D02 A03 B03 Input 2 D03 Ub1 Ub1'D04 A04 B04 Input 3 A05 B05 Input 4 D05 Uc1 Uc1' D06 A06 B06 Input 5 A07 B07 Input 6 D07 U01 U01' D08 A08 B08 Input 7 NET2 D09 Ua2 Ua2' D10 A09 B09 Input 8 A10 B10 Input 9 D11 Ub2 Ub2' D12 A11 B11 Input 10 A12 B12 D13 Uc2 Uc2' D14Input 11 A13 B13 Input 12 D15 U02 U02'D16 A14 B14 Input 13 Run Light A15 B15 Input 14 D17 D18 A16 B16 Input 15 D19 D20 DEBUG D21 D22 D23 D24 A17 KM B17 Input 16 C01 GPS-A A18 B18 Input 17 C02 GPS-B A19 B19 Input 18 C03 A20 B20 Input 29 C04 COM1A A21 B21 Overhaul C05 COM1B A22 B22 (+24V) C06 Shielded ground A23 B23 Common terminal C07 COM2A A24 B24 Trip Signal C08 COM2B A25 B25 Alarm Signal C09 DCS1+ 1.Ua1, Ub1 and Uc1 are Section I Bus protection voltage. A26 B26 C10 DCS1- 2.Ua2, Ub2 and Uc2 are Section II Bus A27 B27 Power off C11 DCS2+ protection voltage.3.U01 is Section I Bus zero sequence A28 B28 Power off C12 DCS2- voltage. A29 B29 Power 4.U02 is Section II Bus zero sequencevoltage. A30 B30 Power 5.Net1,Net2 is ethernet port.COM1,COM 2 is 485 port. A31 B31 6.If +24V on power board is standard A32 B32 Shielded ground configuration or not,it is used as input power supply only when using internal 24V. Figure 1 Terminal diagram of MPTS-810Hc PT paralleling and voltage protection device 22 User’s manual of MPTS-810Hc PT paralleling and voltage protection Device WLD[K]-JY-309-2018 Addendum 2: Typical wiring diagram of the device Ua1Ua1'Ub1Ub1'Uc1Uc1' Ua2Ua2'Ub2Ub2'Uc2Uc2' I Bus Protection I Bus II Bus Protection II Bus Voltage Zero-sequence AC Voltage plug-in unit Zero-sequence Voltage Voltage -KM MPTS-810Hc PT parall signal PT paralleling and voltage protection device earth signal PT failure Net1 I bus Net2 abnormal V II bus abnormal V debugging R.S. output port R.P. output COM A C05 COM B POWER plug-in unit output 1 shielded ground COM A output 2 COM B 4~20mA DCSOut1+ output 3 DCSOut1- DCSOut2+ DCSOut2- output 4 4~20mA output 5 output 6 output 7 Figure 2 Wiring diagram of MPTS-810Hc PT paralleling and voltage protection device 23 CPU plug-in unit input common WC input 18terminal- WC remote/local input 19 input 2 overhaul input 3 24V+ input 4 signal common input 5 trip signal Breaker input 6 alarm signal input 7 input 8 power off input 9 power off input 10 power+ input 11 power- input 12 input 13 shielded ground input 14 PT mon.parallel input 15 PT man.slip input 16 input 17 I/O plug-in unit
样本库微信小程序

微信扫一扫,手机找样本

© 2025 样本库 京ICP备17018997号-1

想要解决产品营销和销售难题?

不妨试试样本通
了解更多