点击查看大图
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182

Renishaw_Programming_Manual_H_2000_6222_0A_B

大小:
586KB
类型:
PDF文档
内容:
共182页
最后更新于:2018年10月11日
32
纠错
全文文本
Programming manual H-2000-6222-0A-B Inspection Plus software for Haas machining centres © 2002–2008 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. Disclaimer RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. Trademarks RENISHAW® and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc. All other brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners. Renishaw part no: H-2000-6222-0A-B Issued: 11.2008 IMPORTANT – PLEASE READ CAREFULLY RENISHAW PRODUCT LICENCE Licensee: you, the person, firm or company accepting the terms of this Licence Renishaw: Renishaw plc, New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR, United Kingdom Product: the software, which is designed to operate on machine tool numeric controllers, supplied by Renishaw for use with Renishaw’s machine tool probing systems Licence to use: a non-exclusive licence to use the Product on a single machine tool only By installing and/or using the Product you indicate your acceptance of the terms of this Licence. Renishaw grants the Licensee a Licence to use the Product on condition the Licensee accepts the following terms and conditions: 1. All rights in and title to the Product are and shall remain vested in Renishaw and its licensors. 2. Renishaw shall replace or repair the Product if it does not materially perform to specification under proper use within 90 days of delivery. This warranty does not apply where the Product has been modified in any manner that is not specifically described in the Product or in the installation or programming manuals supplied with the Product, or where the Product is used with probing systems that have not been produced by Renishaw. Except as stated in this paragraph, all warranties, conditions and terms implied by law are excluded. In particular, no warranty is given that the Product is bug or error-free. 3. NOTE - LIMITATION OF LIABILITY IN CONNECTION WITH USE OF THE PRODUCT Renishaw does not exclude liability for personal injury or death caused by Renishaw’s negligence. Renishaw’s liability is limited to (a) the warranty contained in paragraph 2 and (b) direct losses up to a maximum of £50,000. Renishaw has no liability to the Licensee for any indirect, consequential or economic loss (including, without limitation, loss of data, profits or goodwill). The Product has been designed for use with Renishaw’s machine tool probing systems. Renishaw has no liability for the results of using the Product with another manufacturer’s machine tool probing systems. By accepting the terms of this Licence the Licensee agrees that this limitation of liability is reasonable. 4. The Licensee may not make any copies of the Product except as provided in this Licence or as permitted by applicable law. The Licensee is authorised to make a backup copy of the Product for security purposes. The Licensee must not remove any licence and copyright notices, labels or marks contained in the original and shall ensure all copies contain such notices without modification. 5. If the Product contains electronic manuals the Licensee may print out the manuals in part or in full, provided that the print outs or copies are not supplied to any third party that is not an employee or contractor for the Licensee without Renishaw’s written permission 6. The Licensee shall not reverse engineer, decompile, or modify the Product or re-use any components separately from the Product unless permitted by a specific instruction contained in the Product or the programming or installation manuals supplied with the Product or by applicable law provided that in the latter case, Licensee has first contacted Renishaw to request any information required to interface with Licensee’s other software. 7. The Licensee shall not make the Product available to any third party in any manner whatsoever nor may this Licence and the Product be transferred to a third party without Renishaw’s prior written agreement. Any agreement by Renishaw is conditional on the permitted transferee agreeing to all terms of this Licence and the Licensee not retaining any copies of the Product. Where the Licensee is a reseller of Renishaw’s machine tool probing systems, Licensee may transfer the Product for ultimate use by an end user with Renishaw’s machine tool probing systems. 8. Renishaw shall have the right to terminate this Licence immediately if the Licensee fails to comply with any of these terms and conditions. The Licensee agrees upon receipt of notice of termination from Renishaw to immediately return or destroy all copies of the Product in its possession or control. 9. This Licence is governed by English law and the parties submit to the exclusive jurisdiction of the English courts. Renishaw Product Licence (EN) – Issue 1: February 2007 Form 1 EQUIPMENT REGISTRATION RECORD Please complete this form (and Form 2 overleaf if applicable) after the Renishaw equipment has been installed on your machine. Keep one copy yourself and return a copy to your local Renishaw Customer Support office (refer to www.renishaw.com/contact for the address and telephone number). The Renishaw Installation Engineer should normally complete these forms. MACHINE DETAILS Machine description..................................................................……………......................................................... Machine type........................................................………………......................................................................... Controller................................………………………............................................................................................. Special control options.............................................................................….......................................…............. ....................................................................................................................……………………………….............. ....................................................................................................................……………………………….............. RENISHAW HARDWARE RENISHAW SOFTWARE Inspection probe type .............................................. Inspection disk(s)......................................……............... Interface type .......................................................... ..........................................................................…........... .............................................................................…........ Tool setting probe type ........................................... Tool setting disk(s) ..............................................…....... Interface type .......................................................... ..................................................................................…... ......................................................................................... SPECIAL SWITCHING M CODES (OR OTHER) WHERE APPLICABLE Dual systems only Switch (Spin) probe on .......................................... Switch on inspection probe ............................................ Switch (Spin) probe off .......................................... Switch on tool setting ..................................................... Start/Error signal .................................................... Other ............................................................................. ......................................................................................... ADDITIONAL INFORMATION Tick box if Form 2 overleaf has been filled in. Customer’s name……….................................................................. Customer’s address..….................................................................... Date installed ..........…........................... .....................................…................................................................. ......................................................................................................... Installation engineer …............................ …...................................................................................................... Customer’s tel. no........................……............................................. Date of training........................................ Customer’s contact name………..................................................... Form 2 SOFTWARE DEVIATION RECORD Standard Renishaw kit no. Software disk nos. Reason for deviation Software no. and Comments and corrections Subroutine no. The software product for which these changes are authorised is subject to copyright. A copy of this deviation sheet will be retained by Renishaw plc. A copy of the software amendments must be retained by the customer – they cannot be retained by Renishaw plc. Cautions and disclaimers i ! Caution – Software safety The software you have purchased is used to control the movements of a machine tool. It has been designed to cause the machine to operate in a specified manner under operator control, and has been configured for a particular combination of machine tool hardware and controller. Renishaw has no control over the exact program configuration of the controller with which the software is to be used, nor of the mechanical layout of the machine. Therefore, it is the responsibility of the person putting the software into operation to: ensure that all machine safety guards are in position and are correctly working before commencement of operation; ensure that any manual overrides are disabled before commencement of operation; verify that the program steps invoked by this software are compatible with the controller for which they are intended; ensure that any moves which the machine will be instructed to make under program control would not cause the machine to inflict damage upon itself or upon any person in the vicinity; be thoroughly familiar with the machine tool and its controller and know the location of all emergency stop switches. Publication No. H-2000-6222 ii Cautions and disclaimers Disclaimer This software is prepared with a base number for adjusting the range of #500 series variables used for data storage. The default settings as supplied have been prepared to comply with current Haas recommendations for probe variable use and avoid conflicts with other current Renishaw software packages unless otherwise stated. Checks for possible variable conflicts must always be made during each installation. Current Haas macro variable recommendations: #0 to #33 Volatile (for general use) #100 to #119 Reserved for Haas use #120 to #139 Available for user #140 to #155 Purchased devices (probe, bar feeder, pallet changer, etc.) #156 to #199 Probe use #500 to #519 Reserved for Haas use #520 to #539 Available for user #540 to #555 Purchased devices (probe, bar feeder, pallet changer, etc.) #556 to #599 Probe use Base number setting for macro variables: This documentation shows default variable numbers and typically includes the base number calculation in brackets. Example: #590 (582+8) Publication No. H-2000-6222 Table of contents iii Table of contents Before you begin Before you begin................................................................................................................. 1 Measurement values used in this manual .......................................................................... 1 List of associated publications ............................................................................................ 2 About the Inspection Plus software .................................................................................... 2 Software kit ......................................................................................................................... 2 File 40120882 – basic cycles ...................................................................................... 2 File 40120883 – Option 1 cycles ................................................................................ 2 File 40120884 – Option 2 cycles ................................................................................ 3 File 40120885 – One-touch cycles ............................................................................. 3 Macro memory requirements ............................................................................................. 3 File 40120882 .............................................................................................................. 3 File 40120883 .............................................................................................................. 4 File 40120884 ............................................................................................................. 4 File 40120885 .............................................................................................................. 4 Haas machines ................................................................................................................... 5 Look ahead G103P1.................................................................................................... 5 M codes for probe switching........................................................................................ 5 Special M codes for inspection and tool setting applications ............................................. 5 User selectable M codes ............................................................................................. 5 Example – macros O9008/O9009 (M80/M81)............................................................. 6 Renishaw customer services .............................................................................................. 7 Calling a Renishaw subsidiary office ........................................................................... 7 Chapter 1 Getting started Why calibrate your Renishaw probe?.............................................................................. 1-2 Calibrating in a bored hole............................................................................................... 1-2 Calibrating in a ring gauge............................................................................................... 1-3 Calibrating the probe length............................................................................................. 1-3 Calibration cycles............................................................................................................. 1-3 Chapter 2 Software installation Installing the software ...................................................................................................... 2-2 #562 back-off distance..................................................................................................... 2-2 Settings macro O9724 ..................................................................................................... 2-3 Chapter 3 Optional inputs Optional inputs ................................................................................................................. 3-2 Publication No. H-2000-6222 iv Table of contents Chapter 4 Variable inputs Variable outputs - chart 1................................................................................................. 4-2 Variable outputs - chart 2................................................................................................. 4-3 Chapter 5 Protected positioning cycles Protected positioning (probe trigger monitor) – macro O9810 ........................................ 5-2 Chapter 6 Calibration cycles Calibration cycles – an overview ..................................................................................... 6-2 Calibrating the probe's length – macro O9801 ................................................................ 6-3 Calibrating the stylus X and Y offsets – macro O9802.................................................... 6-5 Calibrating the stylus ball radius – macro O9803 ............................................................ 6-8 Calibrating the vector stylus ball radius – macro O9804 ............................................... 6-11 Example 1 – Full calibration in an internal feature......................................................... 6-14 Example 2 – Full calibration on an external feature ...................................................... 6-16 Chapter 7 Measuring cycles X Y Z single surface measurement – macro O9811........................................................ 7-2 Web / pocket measurement – macro O9812................................................................... 7-5 Bore / boss measurement – macro O9814...................................................................... 7-9 Finding an internal corner – macro O9815 .................................................................... 7-13 Finding an external corner – macro O9816 ................................................................... 7-17 Chapter 8 Vector measuing cycles Angle single surface measurement – macro O9821 ....................................................... 8-2 Angled web or pocket measurement – macro O9822 ..................................................... 8-5 3-point bore or boss measurement – macro O9823........................................................ 8-9 Chapter 9 Additional cycles 4th axis X measurement – macro O9817 ........................................................................ 9-2 4th axis Y measurement – macro O9818 ........................................................................ 9-5 Bore / boss on PCD measurement – macro O9819........................................................ 9-8 Stock allowance – macro O9820................................................................................... 9-11 Storing multi-stylus data – macro O9830 ...................................................................... 9-16 Loading multi-stylus data – macro O9831 ..................................................................... 9-19 Turning the probe on – macro O9832............................................................................ 9-22 Turning the probe off – macro O9833............................................................................ 9-23 Determining feature-to-feature data in the XY plane – macro O9834........................... 9-24 Determining feature-to-feature data in the Z plane – macro O9834.............................. 9-29 Publication No. H-2000-6222 Table of contents v Updating the SPC tool offset – macro O9835 ............................................................... 9-33 Optimising a probing cycle – macro O9836................................................................... 9-35 Angle measurement in the X or Y plane – macro O9843.............................................. 9-38 Chapter 10 Macro alarms General alarms .............................................................................................................. 10-2 Optimisation macro only (O9836) alarms ...................................................................... 10-5 Appendix A Example job Introduction ......................................................................................................................A-2 Probe operations..............................................................................................................A-3 Appendix B Features, cycles and limitations of the Inspection Plus software Features of the Inspection Plus software ........................................................................B-2 Cycles ..............................................................................................................................B-3 Limitations........................................................................................................................B-3 Limitations when using vector cycles O9821, O9822 and O9823............................B-3 Mathematical precision ....................................................................................................B-4 Effect of vector calibration data on results.......................................................................B-4 Appendix C Settings macro details Macro G65P9724.............................................................................................................C-2 Appendix D Tolerances Tolerances .......................................................................................................................D-2 True position tolerances ..................................................................................................D-3 Appendix E Experience values Ee Experience values Ee ......................................................................................................E-2 Reason for using this option ............................................................................................E-2 Appendix F Additional spare tool offsets Additional spare tool offsets............................................................................................. F-2 Appendix G Printing a macro output Example of printing a macro output ................................................................................ G-2 Appendix H Output flow (bore/boss and web/pocket cycles) Output flow (bore/boss and web/pocket cycles) ..............................................................H-2 Publication No. H-2000-6222 vi Table of contents Appendix I Use of macro variables Local variables .................................................................................................................. I-2 Common variables............................................................................................................ I-2 Common retained variables.............................................................................................. I-3 Appendix J General probing applications Example 1 – Part identification ........................................................................................ J-2 Example 2 – Probe measure every nth component ........................................................ J-3 Appendix K One-touch measuring Introduction ......................................................................................................................K-2 Why use a one-touch probe cycle? .................................................................................K-2 Machine distortion............................................................................................................K-2 Comparing cycle times ....................................................................................................K-2 Installing the one-touch cycles.........................................................................................K-3 Macro edits ......................................................................................................................K-3 Measuring the feedrate.............................................................................................K-3 Stand-off and overtravel distance.............................................................................K-3 System operation.............................................................................................................K-4 Using standard skip ..................................................................................................K-4 Additional variables used..........................................................................................K-4 Approach feedrates ..................................................................................................K-4 Back-off distance #562 (556 + 6) .............................................................................K-5 False trigger loop......................................................................................................K-5 Acceleration and deceleration allowance .................................................................K-5 Q input .............................................................................................................................K-6 Measuring move detail.....................................................................................................K-6 One-touch measuring move logic ....................................................................................K-7 Publication No. H-2000-6222 Before you begin 1 Before you begin This programming manual contains detailed information about how to use the Inspection Plus software for programming, operating and controlling a machine tool. Split into ten self-contained chapters, the manual is structured to provide the information that you require to use the Inspection Plus software effectively: Chapter 1, “Getting started” explains why your probe must be calibrated before you start using it. Chapter 2, “Software installation” describes how to install and customise the Inspection Plus software on your machine. Chapter 3, “Optional inputs” provides a complete list of the optional inputs that are required by some of the macro cycles. Chapter 4, “Variable outputs” provides a complete list of the optional outputs that are produced by some of the macro cycles. Chapter 5, “Protected positioning cycles” describes how to use the protected positioning macro (O9810). When correctly used, this macro prevents damage to the probe stylus in the event of the probe colliding with the workpiece. Chapter 6, “Calibration cycles” describes how to use the four macros that are provided for calibrating a probe. Chapter 7, “Measuring cycles” describes how to use the non-vector measuring cycle macros. Chapter 8, “Vector measuring cycles” describes how to use the three vector measuring cycle macros. Chapter 9, “Additional cycles” describes how to use the macro cycles that have not been described in previous chapters. Chapter 10, “Macro alarms” describes the macro alarm numbers or messages that may be displayed on the screen of the machine tool controller when an error occurs. An explanation of the meaning and possible cause of each alarm message is provided, together with typical actions you must take to correct the fault causing the message. Measurement values used in this manual Throughout this manual, metric units of measurement, i.e. millimetres, are used in the examples. The equivalent imperial measurements, i.e. inches, are shown in brackets. Publication No. H-2000-6222 2 Before you begin List of associated publications When you are working with the Inspection Plus software, you may find it useful to refer to the following Renishaw publications: Data sheet Probe software for machine tools (Renishaw part no. H-2000-2289). Installation manual Probe systems for Haas VF series machines (Renishaw part no. H-2000-6221). About the Inspection Plus software For a comprehensive description of the facilities provided by the software and also the limitations of the software, you should refer to Appendix B “Features, cycles and limitations of the Inspection Plus software”. Software kit Inspection Plus software – Renishaw part no. A-4012-0880 This comprises the following item: CD – part no. A-4012-0881 The CD contains the following data: Basic cycles (File 40120882) Option 1 cycles (File 40120883) Option 2 cycles (File 40120884) One-touch probe cycle (File 40120885) File 40120882 – basic cycles O9721 O9722 O9723 O9724 O9726 O9727 O9731 O9732 O9801 O9802 O9803 O9810 O9811 O9812 O9814 The disk is formatted to multi-load all macros. File 40120883 – Option 1 cycles O9730 O9804 O9815 O9816 O9817 O9818 O9821 O9822 O9823 O9834 O9843 The disk is formatted to multi-load all macros. Publication No. H-2000-6222 Before you begin 3 File 40120884 – Option 2 cycles O9819 O9820 O9830 O9831 O9832 O9833 O9835 O9836 The disk is formatted to multi-load all macros. File 40120885 – One-touch cycles O9726 Macro memory requirements This section lists the amount of memory (in Kbytes) that is required by each macro. Before you load macros, you should first work out the total amount of memory required by the macros you wish to load. Next, you should check that the machine's controller has sufficient memory for these macros. Useful memory size conversions: 1 Kb = 2.5 m (8.2 ft) of software tape 8 Kb = 20 m (65.6 ft) of software tape File 40120882 The total amount of memory required for all macros in this file is 13.8 Kb. The memory requirements for each macro are as follows: Macro number and function Memory (Kbytes) O9721 X diameter move 0.594 O9722 Y diameter move 0.578 O9723 Active tool offset macro 0.040 O9724 Setting macro 0.371 O9726 X,Y,Z, basic move 1.526 O9727 Vector diameter move 0.510 O9731 Vector calibration data find 0.658 (also used for ATAN calculation) O9732 Offset update macro 1.220 O9801 Probe length calibration 0.387 O9802 Stylus X,Y offset calibration 0.463 O9803 Stylus ball radius calibration 0.677 O9810 Protected positioning 0.429 O9811 XYZ single surface measure 2.487 O9812 Web pocket measure 2.109 O9814 Bore boss measure 1.673 Publication No. H-2000-6222 4 Before you begin File 40120883 The total amount of memory required for all macros in this file is 26.2 Kb. The memory requirements for each macro are as follows: Macro number and function Memory (Kbytes) O9730 Print macro 3.771 O9804 Vector stylus ball radius calibration 0.991 O9815 Internal measure 2.813 O9816 External measure 2.941 O9817 4th axis X measure 1.536 O9818 4th axis Y measure 1.536 O9821 Angle single surface measure 1.983 O9822 Angle web pocket 2.452 O9823 3-point bore boss 2.839 O9834 Feature-to-feature measure 3.893 O9843 XY plane angle measure 1.401 File 40120884 The total amount of memory required for all macros in this file is 7.5 Kb. The memory requirements for each macro are as follows: Macro number and function Memory (Kbytes) O9819 Bore boss on PCD 1.715 O9820 Stock allowance 2.445 O9830 Multi-stylus store 0.453 O9831 Multi-stylus load 0.453 O9832 Turn-on macro 0.387 O9833 Turn-off macro 0.381 O9835 SPC tool offset update 0.515 O9836 Optimisation macro 1.159 File 40120885 The memory requirements for this file are as follows: Macro number and function Memory (Kbytes) O9726 One-touch cycle 1.690 Publication No. H-2000-6222 Before you begin 5 Haas machines With this control the G103 command is used to limit read ahead. Example G103 P1 Read only one block ahead G65P9810Z10. Protected positioning move G65P9814D50.Z-10. Measure cycle G65P9810Z100. Protected positioning move G103 Cancel read ahead Look ahead G103P1 The Renishaw cycles have G103P1 embedded in macro O9724 to turn the look ahead off during the probe cycle. The G103 command is embedded at the bottom of the cycles to turn look ahead back on at the end of the cycles. M codes for probe switching The software has been modified in macro O9724 to include an M19 orientation. If the spindle re-orients during probing, the M19 may be deleted from O9724 and added to your main program prior to running any probe cycles. If M-codes are being used to turn the probe on or off, they should be edited into O9832/O9833. Special M codes for inspection and tool setting applications User selectable M codes M code called macros for the following functions must be installed for use with the tool setting arm control. M80 Activate tool setting arm (macro O9008). This brings the tool setting arm into the operating position and makes the probe active. M81 Stow tool setting arm (macro O9009). This retracts the tool setting arm and switches off the probe. Publication No. H-2000-6222 6 Before you begin Example – macros O9008/O9009 (M80/M81) O9008(REN M80 ARM ACTIVE) G103P1 G80G40 G91G28Z0(RETURN Z AXIS) G90 M52(ARM DIR. ACT. AND TLSET ON) M53(ARM MOVE COMMAND) #3001=0 N10 IF[#1029EQ0]GOTO20(SKIP STATUS) IF[#3001LT5000]GOTO10 M63 G103 #3000=91(TOOL SET ARM ACTIVE TIME OUT) N20 M63(SWITCH MOVE COMMAND OFF) G103 M99 O9009(REN M81 ARM STOW) G103P1 M62(ARM DIR. STOW. AND INSP ON) M53(ARM MOVE COMMAND) #3001=0 N10 IF[#1021EQ0]GOTO20 IF[#3001LT5000]GOTO10 M63 G103 #3000=91(TOOL SET ARM STOW TIME OUT) N20 M63(SWITCH MOVE COMMAND OFF) G103 M99 % Publication No. H-2000-6222 Before you begin 7 Renishaw customer services Calling a Renishaw subsidiary office If you have a question about the software, first consult the documentation and other information included with your product. If you cannot find a solution, you can receive information on how to obtain customer support by contacting the Renishaw subsidiary company that serves your country (see www.renishaw.com/contact). When you call, it will help the Renishaw support staff if you have the appropriate product documentation at hand. Please give the following information (as applicable): The version of the product you are using (see the equipment registration record form). The type of hardware that you are using (see the equipment registration record form). The exact wording of any messages that appear on your screen. A description of what happened and what you were doing when the problem occurred. A description of how you tried to solve the problem. Publication No. H-2000-6222 8 Before you begin This page is intentionally left blank. Publication No. H-2000-6222 Getting started 1-1 Chapter 1 Getting started Before you start to use the Inspection Plus software, take time to read this chapter. It will provide you with a basic understanding of the importance of accurately calibrating the probe you intend to use for measuring. Only when the probe is accurately calibrated can you achieve total quality control over your manufacturing process. Contained in this chapter Why calibrate your Renishaw probe? .............................................................................. 1-2 Calibrating in a bored hole ............................................................................................... 1-2 Calibrating in a ring gauge ............................................................................................... 1-3 Calibrating the probe length............................................................................................. 1-3 Calibration cycles............................................................................................................. 1-3 Publication No. H-2000-6222 1-2 Getting started Why calibrate your Renishaw probe? In Chapter 6 of this manual you will find details of the macros used to calibrate your Renishaw probe. But why is it so important that your probe is calibrated? When you fit your Renishaw probe into a machine shank/holder, it is not necessary for the stylus to run true to the spindle centre-line. A small amount of run-out can be tolerated, but it is good practice to get the stylus mechanically on-centre to reduce the effects of spindle and tool orientation errors. Without calibration of the probe the run-out will lead to inaccurate results. By calibrating your probe, the run-out is automatically accounted for. The ‘calibration in a bored hole’ cycle (macro O9802) provides the data to allow for this run-out. As each Renishaw probe system is unique, it is imperative that you calibrate it in the following circumstances: If it is the first time your probe system is to be used. If a new stylus is fitted to your probe. If it is suspected that the stylus has become distorted or that the probe has crashed. At regular intervals to compensate for mechanical changes of your machine tool. If repeatability of relocation of the probe’s shank is poor. In this case, the probe may need to be recalibrated each time it is selected. Three different operations are used to calibrate a probe. They are: Calibrating in a bored hole; Calibrating in a ring gauge; and Calibrating the probe length. Calibrating in a bored hole Calibrating your probe in a bored hole automatically stores values for the offset of the stylus ball to the spindle centre line. The stored values are then automatically used in the measuring cycles. They compensate the measured values so that they are relative to the true spindle centre line. Publication No. H-2000-6222 Getting started 1-3 Calibrating in a ring gauge Calibrating your probe in a ring gauge of a known diameter automatically stores one or more values for the radius of the stylus ball. The stored values are then automatically used by the measuring cycles to give the true size of the feature. The values are also used to give true positions of single surface features. NOTE: The stored radii values are based on the true electronic trigger points. These values are different from the physical sizes. Calibrating the probe length Probe length calibration on a known reference surface stores the length based on the electronic trigger point. This is different from the physical length of the probe assembly. Additionally, this operation can automatically compensate for machine and fixture height errors by adjusting the probe length value that is stored. Calibration cycles Four calibration cycles are provided with the Inspection Plus software. These may be used in conjunction with one another for complete calibration of the probe. The function of each macro is summarised below. For further details, refer to Chapter 6, “Calibration cycles”. Macro O9801 This is used to establish the probe length in its tool shank. Macro O9802 This is used to establish the stylus off-centre values. Macro O9803 This is used to establish the stylus ball radius values. It is suitable for all measuring cycles except O9821, O9822 and O9823. Macro O9804 This is used to establish the vector stylus ball radius values. It is suitable for all measuring cycles, including O9821, O9822 and O9823. For complete calibration of a probe system, you must use macros O9801 and O9802, and either O9803 or O9804. The Renishaw calibration cycles are split into separate cycles for flexibility. If, however, the calibration feature is accurately known for both size and position, e.g. a ring gauge where the size is known, and the position is accurately found using a dial test indicator, it is then possible for you to write a program which completes the full calibration procedure in one operation by calling all of the above macros. Publication No. H-2000-6222 1-4 Getting started This page intentionally left blank. Publication No. H-2000-6222 Software installation 2-1 Chapter 2 Software installation This chapter describes how you should load and customise the Inspection Plus software. It supplements the information described in the ‘Software installation’ section of the installation manual titled Probe systems for Haas VF series machines (Renishaw part no. H-2000-6221). Contained in this chapter Installing the software ...................................................................................................... 2-2 #562 back-off distance..................................................................................................... 2-2 Settings macro O9724 ..................................................................................................... 2-3 Publication No. H-2000-6222 2-2 Software installation Installing the software It is important that the software is installed to suit the type of controller and options available. Do this as described below: 1. First, refer to Appendix B, “Features, cycles and limitations of the Inspection Plus software for the MP700 probe” to determine whether the Inspection Plus software for the MP700 probe is suitable for your needs. 2. Decide which cycles you require before proceeding (see the section titled “Macro memory requirements” in the preliminary part of this manual titled “Before you begin”). 3. Load the basic cycles on file 40120892. Delete any unwanted O98-- series cycles. If you intend to calibrate your probe using a bored hole or ring gauge and calibrate the probe length on a known reference surface, then delete macro O9804. Alternatively, if you intend to calibrate on a calibration sphere, then delete macros O9801, O9802 and O9803. 4. Load the Option 1 file 40120893 if required. Delete all unwanted macros from the control before loading further macros. If the print option is not to be used, delete macro O9730. 5. Load the Option 2 file 40120894 if required. Delete all unwanted macros from the control. #562 back-off distance Run the optimisation macro to establish the #562 back-off distance and #169 fast feedrate. Refer to: Appendix I, “Use of macro variables” for a description on the use of macro variables; and Chapter 9, “Additional cycles” for a description on using the optimisation macro O9836. For small and medium size machines, i.e. machines having less than 1000 mm (40 in) of axis travel, the standard feedrates as supplied are normally acceptable. This macro may be deleted by the operator after optimisation is completed. Publication No. H-2000-6228 Software installation 2-3 Settings macro O9724 If the default values are not suitable, you will need to change the settings macro O9724. Refer to Appendix C, “Settings macro details” for a description of macro O9724. Set the following settings macro options: Work offset type Tolerance alarms or flag only (FMS type application) The examples in this document are for general guidance only. Please note that the exact programming format may not suit either your machine set or recommended method as specified by your machine builder. Publication No. H-2000-6222 2-4 Software installation This page intentionally left blank. Publication No. H-2000-6222 Optional inputs 3-1 Chapter 3 Optional inputs This chapter lists and explains the optional inputs that may be applied to some of the macros. You will be referred to this chapter from other chapters when an optional input is required. Further information regarding optional inputs is to be found in the appendices to this manual. Contained in this chapter Optional inputs ................................................................................................................. 3-2 Publication No. H-2000-6222 3-2 Optional inputs Optional inputs The examples described below assume that the controller has been configured for metric values, i.e. millimetres. The equivalent imperial measurement values, i.e. inches, are shown in brackets. Bb b = Angle tolerance of the surface, e.g. 30 degrees ± 1 degree inputs A30.B1. Example: B5. to set a tolerance of 5 degrees. Ee e = Experience value. Specify the number of a spare tool offset where an adjustment value to the measured size is stored (see Appendix E, “Experience value Ee”). Example: E21. causes the experience value stored in tool offset 21 to be applied to the measured size. Ff f = Percent feedback when updating a tool offset (see Appendix D, “Tolerances”). Enter a value between 0 and 1 (0% and 100%). The default value is 100%. Also Feedrate in the protected positioning macro O9810 (see Chapter 5, “Protected positioning cycles”). Example: F15 sets a feedrate of 15 mm/min. (F.6 sets a feedrate of 0.6 in/min.) Hh h = The tolerance value of a feature dimension being measured. Example: For dimension 50.0 mm +0.4 mm –0 mm, the nominal tolerance is 50.2 mm with H.2. (For dimension 1.968 in +0.016 in –0 in, the nominal tolerance is 1.976 in with H.008.) Ii Jj See the relevant measuring cycles and specific macro calls. Kk Mm m = This is the true position tolerance of a feature. A cylindrical zone about the theoretical position. Example: M.1 sets a true position tolerance of 0.1 mm. (M.004 sets a true position tolerance of 0.004 in.) Qq q = This is the probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Also used in the optimisation macro O9836 (see Chapter 9, “Additional cycles” for details). Publication No. H-2000-6222 Optional inputs 3-3 Example: Q8. sets an overtravel distance of 8 mm. (Q.3 sets an overtravel distance of 0.3 in.) Rr r = This is an incremental dimension that is used in external features, e.g. bosses and webs, to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). Example: R10. sets a radial clearance of 10 mm. (R.4 sets a radial clearance of 0.4 in.) R-r -r = This is similar to Rr, except that the clearance is applied in the opposite direction to force an internal boss or web cycle. Default value is 5 mm (0.200 in). Example: R-10. sets a radial clearance of -10 mm. (R-.4 sets a radial clearance of -0.4 in.) Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Example: S3. Tt t = This is the tool offset number to be updated Example: T20 updates tool offset number 20. Uu u = Upper tolerance limit. If this value is exceeded there is no tool offset or work offset updated and the cycle is stopped with an alarm. This tolerance is applied to both size and position where applicable. Example: U2. to set the upper tolerance limit to 2 mm. (U.08 to set the upper tolerance limit to 0.08 in.) Vv v = Null Band. This is the tolerance zone where no tool offset adjustment occurs. The default value is 0. Example: V.5 for a tolerance zone of ±0.5 mm. (V.02 for a tolerance zone of ±0.02 in.) Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. Example: W1. Publication No. H-2000-6222 3-4 Optional inputs This page intentionally left blank. Publication No. H-2000-6222 Variable inputs 4-1 Chapter 4 Variable inputs This chapter lists the variable outputs that may be produced by some of the macros. You will be referred to this chapter from other chapters when a variable output is produced. Contained in this chapter Variable outputs - chart 1................................................................................................. 4-2 Variable outputs - chart 2................................................................................................. 4-3 Publication No. H-2000-6222 4-2 Variable inputs Variable outputs - chart 1 Single Web/ Bore/boss Internal External 4th axis XY angle surface pocket corner corner measure G65P9811 G65P9812 G65P9814 G65P9815 G65P9816 G65P9817/18 G65P9843 #185 X position X position X position X position X position #186 Y position Y position Y position Y position Y position #187 Z position #188 Size Size Size #189 X surface X surface 4th angle Angle angle angle #190 X error X error X error X error X error #191 Y error Y error Y error Y error Y error #192 Z error Y surface Y surface angle angle #193 Size error Size error Size error Y angle Y angle Height error Height error error error #194 X angle X angle Angle error Angle error error error #195 True True True True True position position position position position error error error error error #196 Metal Metal Metal condition condition condition #197 Direction indicator #198 Out of tolerance flag (1 to 7) #199 Probe error flag (0 to 2) Publication No. H-2000-6222 Variable inputs 4-3 Variable outputs - chart 2 PCD Stock Angle single Angle 3-point Feature to bore/boss allowance surface web/pocket bore/boss feature G65P9819 G65P9820 G65P9821 G65P9822 G65P9823 G65P9834 #185 X position X position X position X position X incremental from start distance #186 Y position Y position Y position Y position Y incremental from start distance #187 PCD Z incremental position #188 Size Size from start Size Size Minimum distance #189 Angle Angle #190 X error X error X error X error X error #191 Y error Y error Y error Y error Y error #192 PCD error Z error #193 Size error Size error Size error Size error Minimum distance error #194 Angle error Maximum Angle error value #195 True position Minimum True position True position True position True position error value error error error error #196 Metal Variation Metal Metal Metal Metal condition (stock) condition condition condition condition #197 Hole number Direction indicator #198 Out of tolerance flag (1 to 7) #199 Probe error flag (0 to 2) Publication No. H-2000-6222 4-4 Variable inputs This page intentionally left blank. Publication No. H-2000-6222 Protected positioning cycles 5-1 Chapter 5 Protected positioning cycles When the probe moves around the workpiece, it is important that the stylus is protected against a collision with the workpiece. This chapter describes how to use macro O9810 to set up the protected positioning of the probe. After it is correctly set, the probe will stop moving in the event of a collision. Contained in this chapter Protected positioning (probe trigger monitor) – macro O9810......................................... 5-2 Publication No. H-2000-6222 5-2 Protected positioning cycles Protected positioning (probe trigger monitor) – macro O9810 Figure 5.1 Probe protected positioning Description It is important when moving around the workpiece to protect the probe stylus against collision. When this cycle is used, the machine will stop in the event of a collision. Application Select the probe and move to a safe plane. The probe should be made active at this point and then it can be moved to a measuring position using this macro call. In the event of a collision, the machine will stop and a macro alarm PATH OBSTRUCTED will result, or an error flag #198 will be set (see Mm input). Format G65 P9810 Xx Yy Zz [Ff Mm] where [ ] denote optional inputs Example: G65 P9810 Z10. F0.8 M0.2 Publication No. H-2000-6222 Protected positioning cycles 5-3 Inputs Xx,Yy,Zz x,y,z = These are the target positions for the probe positioning move. Ff f = The modal feedrate for all protected positioning moves. The feedrate will be modal to this macro and subsequent feedrate calls are unnecessary unless a change of feedrate is required. The maximum safe fast feedrate established during installation should not be exceeded. Mm m = 1.0 Will set a probe trigger flag (no PATH OBSTRUCTED alarm) #198 = 0 (no probe trigger) #198 = 7 (probe triggered) Example G1G54X20.Y50. G43H20Z100. Move to a safe plane. G65P9832 Spin the probe on (includes M19) or M19 for spindle orientation. G65P9810Z10.F3000 Protected positioning move. G65P9811Z0S1 Single surface measure. Publication No. H-2000-6222 5-4 Protected positioning cycles This page intentionally left blank. Publication No. H-2000-6222 Calibration cycles 6-1 Chapter 6 Calibration cycles Before a probe is used, it is important that you calibrate it correctly. This chapter describes the four macros that you should use for calibrating a probe. If you need to know more about calibrating a probe, you will find helpful information contained in Chapter 1, “Getting started”. Contained in this chapter Calibration cycles – an overview...................................................................................... 6-2 Calibrating the probe's length – macro O9801................................................................. 6-3 Calibrating the stylus X and Y offsets – macro O9802 .................................................... 6-5 Calibrating the stylus ball radius – macro O9803 ............................................................ 6-8 Calibrating the vector stylus ball radius – macro O9804................................................ 6-11 Example 1 – Full calibration in an internal feature ......................................................... 6-14 Example 2 – Full calibration on an external feature....................................................... 6-16 Publication No. H-2000-6222 6-2 Calibration cycles Calibration cycles – an overview Four calibration cycles are provided with the Inspection Plus software. These may be used in conjunction with one another for complete calibration of the probe. The purpose of each macro is summarised below. Macro O9801 This is used to establish the probe's length in its tool shank. Macro O9802 This is used to establish the stylus off-centre values. Macro O9803 This is used to establish the stylus ball radius values. It is suitable for all measuring cycles except for O9821, O9822 and O9823. Macro O9804 This is used to establish the vector stylus ball radius values. It is suitable for all measuring cycles, including O9821, O9822 and O9823. For complete calibration of a probe system, you must use macros O9801 and O9802, and either O9803 or O9804. Examples of full calibration procedures are described in the sections titled “Example 1 – Full calibration in an internal feature” and “Example 2 – Full calibration on an external feature” at the end of this chapter. The Renishaw calibration cycles are split into separate cycles for flexibility. If, however, the calibration feature is accurately known for both size and position, e.g. a ring gauge where the size is known, and the position is accurately found using a dial test indicator, it is then possible for you to write a program which completes the full calibration procedure in one operation by calling all of the above macros. Publication No. H-2000-6222 Calibration cycles 6-3 Calibrating the probe's length – macro O9801 Tt Tool offset Zz Ref. height Z Y X Figure 6.1 Calibrating the probe's length Description The probe is positioned adjacent to a Z axis reference surface for calibration. When the cycle is completed, the active probe tool offset is adjusted to the reference surface. Application Load an approximate tool offset. The probe should be positioned adjacent to the reference surface. When the cycle is run, the surface is measured and the tool offset is reset to a new value. The probe is returned to the start position. Format G65 P9801 Zz Tt Example: G65 P9801 Z50. T20 Publication No. H-2000-6222 6-4 Calibration cycles Compulsory inputs Zz z = Reference surface position Tt t = The active tool offset number. Outputs The active tool offset will be set. Example Set X, Y, Z values in work offset G54 O 0001 G90G80G40G0 Preparatory codes for the machine. G54X0Y0 Start position. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). G65P9832 Spin the probe on (includes M19) or M19 for spindle orientation. G65P9810Z10.F3000 Protected positioning move. G65P9801Z0T1 Datum Z direction. G65P9810Z100. Protected positioning move. G65P9833 Spin the probe off (when applicable). G28Z100. Reference return. H00 Cancel offset. M30 End of program NOTE: The tool offset must be active. The active tool offset H word number must be the same as the T input number (see above) Publication No. H-2000-6222 Calibration cycles 6-5 Calibrating the stylus X and Y offsets – macro O9802 4 1 2 #558 Y 3 Zz X Dd Figure 6.2 Calibrating the stylus X and Y offsets Description The probe is positioned inside a pre-machined hole at a suitable height for calibration. When this cycle is completed, the stylus offset amounts in the X and Y axes are stored. Application Pre-machine a hole with a suitable boring bar, so that the exact centre of the hole is known. Position the probe to be calibrated inside the hole, and the spindle on the known centre position with the spindle orientation active. When the cycle is run, four measuring moves are made in order to determine the X offset and Y offset of the stylus. The probe is then returned to the start position. Format G65 P9802 Dd [Zz] where [ ] denote optional inputs Example: G65 P9802 D50.005 Z50. Compulsory inputs Dd d = Nominal size of feature Publication No. H-2000-6222 6-6 Calibration cycles Optional input Zz z = The absolute Z axis measuring position when calibrating on an external feature. If this is omitted, a bore cycle is assumed. Outputs The following data will be stored as shown: #558 (556 + 2) = X axis stylus offset #559 (556 + 3) = Y axis stylus offset Example Stylus X, Y offset calibration A tool offset must be active before running this program Position the stylus in the bored hole at the required depth. The spindle centre must be positioned exactly on the bored hole centre line. O0002 G90G80G40G0 Preparatory codes for the machine. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9802D50. Calibrate in a 50 mm (1.97 in) diameter bored hole. G65P9833 Spin the probe off (when applicable). M30 End of program. Alternatively Run a complete positioning and calibration program as follows. Set the exact X,Y, Z feature positions in a work offset (example using G54). O0002 G90G80G40G0 Preparatory codes for the machine. G54X0Y0 Move to centre of the feature. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9810Z-5.F3000 Protected positioning move into hole. Publication No. H-2000-6222 Calibration cycles 6-7 G65P9802D50. Calibrate in a 50 mm (1.97 in) diameter bored hole. G65P9810Z100.F3000 Protected positioning move retract to 100 mm (3.94 in). G65P9833 Spin the probe off (when applicable). G28Z100. Reference return. H00 Cancel offset (when applicable). M30 End of program Publication No. H-2000-6222 6-8 Calibration cycles Calibrating the stylus ball radius – macro O9803 NOTE: Do not use this cycle to calibrate the radius of the stylus ball if, subsequently, you intend using vector measuring macros O9821, O9822 or O9823. The stylus ball radius must be calibrated using macro O9804 instead. 4 #556 1 2#557 5 6 Y Zz 3 X Dd Figure 6.3 Calibrating the stylus ball radius Description The probe is positioned inside a calibrated ring gauge at a suitable height for calibration. When this cycle is completed, the stylus ball radius values are stored. Application Clamp a calibrated ring gauge on the machine table at an approximately known position. Position the probe to be calibrated inside the ring gauge on the approximate centre position, with spindle orientation active. When the cycle is run, six moves are made in order to determine the stylus ball radius values. The probe is then returned to the start position. Format G65 P9803 Dd [Zz Ss] where [ ] denote optional inputs Example: G65 P9803 D50.005 Z50. S1. Publication No. H-2000-6222 Calibration cycles 6-9 Compulsory inputs Dd d = Reference gauge size Optional inputs Zz z = The absolute Z axis measuring position when calibrating on an external feature. If this is omitted, a ring gauge cycle is assumed. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Outputs The following data will be stored as shown: #556 (556 + 0) = X+, X-, stylus ball radius (XRAD) #557 (556 + 1) = Y+, Y-, stylus ball radius (YRAD) Example Stylus ball radius calibration A tool offset must be active before running this program. If your machine does not retain the offset then use the alternative example. Position the probe's stylus approximately on-centre in the ring gauge and at the required depth. O0003 G90G80G40G0 Preparatory codes for the machine. G65P9832 Spin the probe on (includes M19) or M19 for spindle orientation. G65P9803D50.001 Calibrate in a 50.001 mm (1.9685 in) diameter ring gauge. G65P9833 Spin the probe off (when applicable). M30 End of program. Publication No. H-2000-6222 6-10 Calibration cycles Alternatively Run a complete positioning and calibration program as follows. Set the approximate X, Y, Z feature positions in a work offset (example using G54). O0003 G90G80G40G00 Preparatory codes for the machine. G54X0Y0 Move to centre of feature. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9810Z-5.F3000 Protected positioning move into hole. G65P9803D50.001 Calibrate in a 50.001 mm (1.9685 in) ring gauge. G65P9810Z100.F3000 Protected positioning move retract to 100 mm (3.94 in). G65P9833 Spin the probe off (when applicable). G28Z100. Reference return. H00 Cancel offset (when applicable). M30 End of program. Publication No. H-2000-6222 Calibration cycles 6-11 Calibrating the vector stylus ball radius – macro O9804 NOTE: You must use this cycle to calibrate the radius of the stylus ball if you intend using vector measuring macros O9821, O9822 or O9823 (described in Chapter 8, “Vector measuring cycles”). Do not calibrate the stylus ball radius using macro O9803. Additional vector moves (7 to 14) at every 30° 4 #557 #556 1 2 5 6 Y Zz3 X Dd Figure 6.4 Calibrating the vector stylus ball radius Description The probe is positioned inside a calibrated ring gauge at a suitable height for calibration. When the cycle is completed, the stylus ball radius values are stored. A total of twelve calibration radii at 30 degree intervals are established. Application Clamp a calibrated ring gauge on the machine table at an approximately known position. The probe to be calibrated is positioned inside the ring gauge on the approximate centre position, with spindle orientation active. When the cycle is run, fourteen moves are made in order to determine the stylus ball radius values. The probe is then returned to the start position. Format G65 P9804 Dd [Zz Ss] where [ ] denote optional inputs Example: G65 P9804 D50.005 Z50. S1. Publication No. H-2000-6222 6-12 Calibration cycles Compulsory inputs Dd d = Reference gauge size. Optional inputs Zz z = The absolute Z axis measuring position when calibrating on an external feature. If this is omitted, a ring gauge cycle is assumed. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Outputs The following data will be stored as shown (as O9803): #556 (556 + 0) = X+, X-, stylus ball radius (XRAD) #557 (556 + 1) = Y+, Y-, stylus ball radius (YRAD) Additional vector calibration data: #566 (556 + 10) = 30 degree stylus ball radius (VRAD) #567 (556 + 11) = 60 degree stylus ball radius (VRAD) #568 (556 + 12) = 120 degree stylus ball radius (VRAD) #569 (556 + 13) = 150 degree stylus ball radius (VRAD) #570 (556 + 14) = 210 degree stylus ball radius (VRAD) #571 (556 + 15) = 240 degree stylus ball radius (VRAD) #572 (556 + 16) = 300 degree stylus ball radius (VRAD) #573 (556 + 17) = 330 degree stylus ball radius (VRAD) Example Vector stylus ball radius calibration A tool offset must be active before running this program. If your machine does not retain the offset, then use the alternative example. Position the probe approximately on-centre in the ring gauge and at the required depth. O0004 G90G80G40G0 Preparatory codes for the machine. Publication No. H-2000-6222 Calibration cycles 6-13 G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9804D50.001 Calibrate in a 50.001 mm (1.9685 in) diameter ring gauge. G65P9833 Spin the probe off (when applicable). M30 End of program. Alternatively Run a complete positioning and calibration program as follows. Set the approximate X, Y, Z feature positions in a work offset (example using G54). O0004 G90G80G40G0 Preparatory codes for the machine. G54X0Y0 Move to centre of feature. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9810Z-5.F3000 Protected positioning move into the hole. G65P9804D50.001 Calibrate in a 50.001 mm (1.9685 in) diameter ring gauge. G65P9810Z100.F3000 Protected positioning move retract to 100 mm (3.94 in). G65P9833 Spin the probe off (when applicable). G28Z100. Reference return. H00 Cancel offset (when applicable). M30 End of program. Publication No. H-2000-6222 6-14 Calibration cycles Example 1 – Full calibration in an internal feature This example describes how to carry out full calibration of the probe in an internal feature using macros O9801, O9802 and O9804, using a 50.001 mm (1.9685 in) diameter ring gauge, with a known centre position and top face height value. The approximate probe length must be stored in the tool offset register before running this program. Set the exact X, Y, and Z feature positions in a work offset (example using G54). 1 2 12 3 11 4 10 6 7 5 8 and 9 Figure 6.5 Full calibration in an internal feature O0006 G90G80G40G0 Preparatory codes for the machine. 1. G54X35.Y0 Move off centre of feature for height setting. 2. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. 3. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 4. G65P9810Z30.F3000 Protected positioning move above reference surface. 5. G65P9801Z20.006T1. Calibrate the probe length. Surface at 20.006 mm (0.7876 in) 6. G65P9810X0Y0 Protected positioning move to centre. 7. G65P9810Z5. Protected positioning move into hole. 8. G65P9802D50. Calibrate in a 50 mm (1.97 in) diameter bored hole to establish the X,Y stylus offset. Publication No. H-2000-6222 Calibration cycles 6-15 9. G65P9804D50.001 Calibrate in a 50.001 mm (1.9685 in) diameter ring gauge to establish the ball radius values, including the vector directions. 10. G65P9810Z100.F3000 Protected positioning move retract to 100 mm (3.94 in). 11. G65P9833 Spin the probe off (when applicable). 12. G28Z100. Reference return. H00 Cancel offset (when applicable) M30 End of program Publication No. H-2000-6222 6-16 Calibration cycles Example 2 – Full calibration on an external feature This example describes how to carry out full calibration of the probe on an external feature using macros O9801, O9802 and O9804, using a 50.001 mm (1.9685 in) diameter pin gauge, with a known centre position and a Z reference surface. The approximate probe length must be stored in the tool offset register before running this program. Set the exact X, Y pin feature positions and Z surface height in a work offset (example using G54). 1 2 11 3 10 4 7 and 8 9 6 5 Figure 6.6 Full calibration on an external feature O0006 G90G80G40G0 Preparatory codes for the machine. 1. G54X135.Y100. Move to centre of feature for height setting. 2. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. 3. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 4. G65P9810Z30.F3000 Protected positioning move above reference surface. 5. G65P9801Z0.T1. Calibrate the probe length. Z surface at zero. 6. G65P9810X100.Y100. Protected positioning move to centre. 7. G65P9802D50.001Z10. Calibrate on a 50.001 mm (1.9685 in) diameter pin gauge to establish the X,Y stylus offset. 8. G65P9804D50.001Z10. Calibrate on a 50.001 mm (1.9685 in) diameter pin gauge to establish the ball radius values, including the vector directions. Publication No. H-2000-6222 Calibration cycles 6-17 9. G65P9810Z100.F3000 Protected positioning move retract to 100 mm (3.94 in). 10. G65P9833 Spin the probe off (when applicable). 11. G28Z100. Reference return. H00 Cancel offset (when applicable) M30 End of program Publication No. H-2000-6222 6-18 Calibration cycles This page intentionally left blank. Publication No. H-2000-6222 Measuring cycles 7-1 Chapter 7 Measuring cycles This chapter describes how to use the non-vector measuring cycle macros. The probe stylus ball radius must be calibrated using either macro O9803 or O9804 (see Chapter 6, “Calibration cycles”) before using the macros described here. Contained in this chapter X Y Z single surface measurement – macro O9811 ........................................................ 7-2 Web / pocket measurement – macro O9812 ................................................................... 7-5 Bore / boss measurement – macro O9814 ...................................................................... 7-9 Finding an internal corner – macro O9815..................................................................... 7-13 Finding an external corner – macro O9816.................................................................... 7-17 Publication No. H-2000-6222 7-2 Measuring cycles X Y Z single surface measurement – macro O9811 Z X,Y Figure 7.1 Measurement of a single surface Description This cycle measures a surface to establish the size or position. Application The probe should be positioned with its tool offset active adjacent to the surface. The cycle measures the surface and returns to the start position. There are two possibilities as follows: 1. The surface can be treated as a size, where the tool offset is updated in conjunction with the Tt and the Hh input. 2. The surface can be treated as a reference surface position, for the purpose of adjusting a work offset using the Ss and Mm inputs. Format G65 P9811 Xx or Yy or Zz [Ee Ff Hh Mm Qq Ss Tt Uu Vv Ww] where [ ] denote optional inputs Example: G65 P9811 X50. E0.005 F0.8 H0.2 M.2 Q10. S1. T20. U.5V.5W2. Publication No. H-2000-6222 Measuring cycles 7-3 Compulsory inputs Xx or Yy or Zz x,y,z = The surface position or size. Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated . Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv see Chapter 3, “Optional inputs”. Publication No. H-2000-6222 7-4 Measuring cycles Example X and Z single surface measurement 1. T01M06 Select the probe. 1 2 2. G54X-40.Y20. Start position. 3 12 3. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). 11 4 5 4. G65P9832 Spin the probe on (includes M19), or M19 10 8 for spindle orientation. 9 7 5. G65P9810Z-8.F3000 Protected positioning move to start position. 6 Z 6. G65P9811X-50.T10. Single surface measure. Y 7. G65P9810Z10. Protected positioning move. X 8. G65P9810X-60. Protected positioning move. Figure 7.2 Probe movements 9. G65P9811Z0T11 Single surface measure. 10. G65P9810Z100. Protected positioning move. 11. G65P9833 Spin the probe off (where applicable). 12. G28Z100. Reference return. continue The tool radius offset (10) is updated by the error of surface position. Publication No. H-2000-6222 Measuring cycles 7-5 Web / pocket measurement – macro O9812 Z0 Zz Z0 Rr Xx, Yy Xx, Yy Z0 Zz Z Y X R-r Xx, Yy Figure 7.3 Measurement of a web or pocket feature Description This cycle measures a web or pocket feature. It uses two measuring moves along the X Y axis. Application Position the probe to the expected centre line of the feature and a suitable position in the Z axis with the probe and probe offset active. Run the cycle with suitable inputs as described. Publication No. H-2000-6222 7-6 Measuring cycles Format G65 P9812 Xx [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9812 Yy [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9812 Xx Zz [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9812 Yy Zz [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] where [ ] denote optional inputs Example: G65 P9812 X50. Z100. E0.005 F0.8 H0.2 M.2 Q10. R10. S1. T20. U.5 V.5 W2. Compulsory inputs Xx x = Nominal size of feature when measured in the X axis. or Yy y = Nominal size of feature when measured in the Y axis. Zz z = The absolute Z axis position when measuring a web feature. If this is omitted a pocket cycle is assumed. Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Rr r = This is an incremental dimension that is used in external features, e.g. bosses and webs, to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). R-r -r = This is similar to Rr, except that the clearance is applied in the opposite direction to force an internal web cycle. Default value is 5 mm (0.200 in). Publication No. H-2000-6222 Measuring cycles 7-7 Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). Example 1 Web measurement 1 2 1. T01M06 Select the probe. 9 3 2. G54X0Y0 Start position. 4 8 3. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in) above. 5 7 4. G65P9832 Spin the probe on (includes M19), or M19 6 for spindle orientation. 5. G65P9810Z10.F3000 Protected positioning move. 6. G65P9812X50.Z-10.S2 Measure a 50.0 mm (1.968 in) wide web. Z Y 7. G65P9810Z100. Protected positioning move. X 8. G65P9833 Spin the probe off (where applicable). Figure 7.4 Probe movements 9. G28Z100. Reference return. continue The feature centre line in the X axis is stored in the work offset 02 (G55). Publication No. H-2000-6222 7-8 Measuring cycles Example 2 Pocket measurement (referred datum) 1 2 1. T01M06 Select the probe. 9 3 2. G54X100.Y50. Start position. 4 8 5 3. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). 7 6 4. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 5. G65P9810Z-10.F3000. Protected positioning move. G55 6. G65P9812X30.S2 Measure a 30.0 mm (1.181 in) wide pocket. Z Y 7. G65P9810Z100. Protected positioning move. X 8. G65P9833 Spin the probe off (where applicable). Figure 7.5 Probe movements 9. G28Z100. Reference return. continue The error of centre line is referred to the datum point X0 and the revised X0 position is set in work offset 02 (G55). Publication No. H-2000-6222 Measuring cycles 7-9 Bore / boss measurement – macro O9814 Z0 Zz Z0.0 Rr Dd dia Dd dia Z0 Zz Z Y X R-r Dd dia Figure 7.6 Measurement of a bore or boss feature Description This cycle measures a bore or boss feature. It uses four measuring moves along the X Y axis. Application Position the probe to the expected centre line of the feature and a suitable position in the Z axis with the probe and probe offset active. Run the cycle with suitable inputs as described. Publication No. H-2000-6222 7-10 Measuring cycles Format G65 P9814 Dd [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9814 Dd Zz [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] where [ ] denote optional inputs Example: G65 P9814 D50.005 Z100. E0.005 F0.8 H0.2 M.2 Q10. R10. S1. T20. U.5 V.5 W2. Compulsory inputs Dd d = Nominal size of the feature. Zz z = The absolute Z axis position when measuring a boss feature. If this is omitted, a bore cycle is assumed. Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Rr r = This is an incremental dimension that is used in external features, e.g. bosses and webs, to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). R-r -r = This is similar to Rr, except that the clearance is applied in the opposite direction to force an internal boss cycle. Default value is 5 mm (0.200 in). Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated. Publication No. H-2000-6222 Measuring cycles 7-11 Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). Example 1 Boss measurement 1 2 1. T01M06 Select the probe. 3 9 2. G54X0Y0 Start position. 8 4 5 3. G43H1Z100. Activate offset 1, go to 100 mm 7 (3.94 in). 6 4. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 5. G65P9810Z10.F3000 Protected positioning move. 6. G65P9814D50.Z-10.S2.R10. Measure a 50.0 mm (1.968 in) diameter boss. G55 7. G65P9810Z100. Protected positioning move. Z Y 8. G65P9833 Spin the probe off (when applicable). X 9. G28Z100. Reference return. Figure 7.7 continue Probe movements The feature centre line in the X and Y axis is stored in the work offset 02 (G55). Publication No. H-2000-6222 7-12 Measuring cycles Example 2 1 2 Bore measurement (referred datum) 1. T01M06 Select the probe. 3 9 2. G54X100.0Y100. Start position. 4 3. G43H1Z100. Activate offset 1, go to 100 mm 8 (3.94 in). 7 5 4. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 5. G65P9810Z-10.F3000 Protected positioning move. 6 6. G65P9814D30.S2 Measure a 30.0 mm (1.181 in) diameter bore. G55 7. G65P9810Z100. Protected positioning move. Z 8. G65P9833 Spin the probe off (when applicable) Y X 9. G28Z100. Reference return Figure 7.8 continue Probe movements The error of centre line is referred to the datum point X0, Y0 and the revised X0, Y0 position is set in work offset 02 (G55). Publication No. H-2000-6222 Measuring cycles 7-13 Finding an internal corner – macro O9815 Xx Yy Yy Ii Jj Y X Figure 7.9 Finding an internal corner position Description This cycle is used to establish the corner position of a feature. NOTE: A true corner intersection can be found, even if the corner is not 90 degrees. Application The probe must be positioned with its tool offset active at a start position as shown in the figure above. The probe measures the Y axis surface first and then measures the X axis surface. The probe then returns to the start position. Errors occurring during the cycle return the probe to the start position. NOTE: If the I and J inputs are missing, only two gauging moves occur. The corner feature is assumed to be parallel to the axes. If either I or J are missing then three gauging moves occur and the corner feature is assumed to be 90 degrees. Format G65 P9815 Xx Yy [Bb Ii Jj Mm Qq Ss Uu Ww] where [ ] denote optional inputs Example: G65 P9815 X100. Y100. B2. I10. J10. M.2 Q10. S1. U.5 W2. Publication No. H-2000-6222 7-14 Measuring cycles NOTE: I and J must be stated in this order if used. Compulsory inputs Xx x = Nominal corner position X axis. Yy y = Nominal corner position Y axis. Optional inputs Bb b = Angle tolerance. This applies to both X and Y surfaces. It is equal to half the total tolerance, e.g. ±0.25 degrees = B.25 tolerance. Ii I = Incremental distance to the second probe position along the X axis (positive value is assumed) (default no move) Jj j = Incremental distance to the second probe position along the Y axis (positive value is assumed) (default no move). Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Uu, see Chapter 3, “Optional inputs”. Publication No. H-2000-6222 Measuring cycles 7-15 Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). W2. Component no. +1 feature no. 1 W1 Feature no. +1 The following will be output: 1. Corner positions 2. Tolerance if used 3. Error in the X axis 4. Error in the Y axis 5. Work offset no. if used Ss The work offset stated will be set such that the nominal X Y positions will be corrected. Mm) See Appendix H, “Output flow“ for the general output structure Uu ) NOTE: #189 is the angle of the X surface and is measured from the X+ axis direction. #192 is the angle of the Y surface and is also measured from the X+ axis direction. Publication No. H-2000-6222 7-16 Measuring cycles Example Finding an internal corner NOTE: Co-ordinate rotation. It is possible to implement rotation using G68/G69 when the control option is available. 1. T01M06 Select the probe. 2 1 2. G54X10.0Y10. Start position. 9 3 3. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). 8 4 4. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 7 5 11 5. G65P9810Z-5.F3000 Protected positioning move. 6 6. G65P9815X20.Y20.I10.J10. Corner find. 7. G65P9810Z100. Protected positioning move. 8. G65P9833 Spin the probe off (where applicable) Z Y 9. G28Z100. Reference return. 10. G17 Select plane. X Figure 7.10 11. G68X#185Y#186R#189 Set rotational position and angle. Probe movements continue machining continue 12. G69 Cancel rotation mode. Publication No. H-2000-6222 Measuring cycles 7-17 Finding an external corner – macro O9816 Ii c d NOTE: The start point establishes the distance to the first measuring position. Yy a b NOTE: a and b are equal c and d are equal Jj Xx Figure 7.11 Finding an external corner Description This cycle is used to establish the corner position of a feature. NOTE: A true corner intersection can be found, even if the corner is not 90 degrees. Application The probe must be positioned with its tool offset active at a start position as shown in the diagram. The probe measures the Y axis surface first and then measures the X axis surface. The probe then returns to the start position. Errors occurring during the cycle return the probe to the start position. NOTE: If the I and J inputs are missing, only two gauging moves occur. The corner feature is assumed to be parallel to the axes. If either I or J are missing then three gauging moves occur and the corner feature is assumed to be 90 degrees. Publication No. H-2000-6222 7-18 Measuring cycles Format G65 P9816 Xx Yy [Bb Ii Jj Mm Qq Ss Uu Ww] where [ ] denote optional inputs Example: G65 P9816 X100. Y100. B2. I10. J10. M.2 Q10. S1. U.5W2. NOTE: I and J must be stated in this order if used. Compulsory inputs Xx x = Nominal corner position X axis. Yy y = Nominal corner position Y axis. Optional inputs Bb b = Angle tolerance. This applies to both X and Y surfaces. It is equal to half the total tolerance, e.g. ±0.25 degrees = B.25 tolerance. Ii I = Incremental distance to the second probe position along the X axis (a positive value is assumed). The default is no move. Jj j = Incremental distance to the second probe position along the Y axis (a positive value is assumed). The default is no move. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe will then travel beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Publication No. H-2000-6222 Measuring cycles 7-19 Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Uu, see Chapter 3, ”Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). W2. Component no. + 1, feature no. set to 1. W1. Feature no. +1 The following will be output: 1. Corner positions 2. Tolerance if used 3. Error in the X axis 4. Error in the Y axis 5. Work offset no. if used Ss The work offset stated will be set such that the nominal X Y positions will be corrected. Mm) See Appendix H, “Output flow” for the general output structure. Uu ) NOTE: #189 is the angle of the X surface and is measured from the X+ axis direction. #192 is the angle of the Y surface and is also measured from the X+ axis direction. Publication No. H-2000-6222 7-20 Measuring cycles Example Finding an external corner NOTE: Co-ordinate rotation. It is possible to implement rotation using G68/G69 when the control option is available. 1. T01M06 Select the probe. 2 1 2. G54X-10.Y-10. Start position. 3. G43H1Z100. Activate offset 1, go to 100 mm 9 3 (3.94 in). 8 4 4. G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. 7 5 11 5. G65P9810Z-5.F3000 Protected positioning move. 6. G65P9816X0Y0I10.J10. Corner find. 6 7. G65P9810Z100. Protected positioning move. 8. G65P9833 Spin the probe off (where Z applicable). Y 9. G28Z100. Reference return. X 10. G17 Select plane. Figure 7.12 11. G68X#185Y#186R#189 Set corner position and angle. Probe movements Continue machining 12. G69 Cancel co-ordinate rotation mode. Publication No. H-2000-6222 Vector measuring cycles 8-1 Chapter 8 Vector measuring cycles This chapter describes how to use the vector measuring cycle macros. The probe stylus ball radius must be calibrated using macro O9804 (see Chapter 6, “Calibration cycles”) before using the macros described here. Do not use macro O9803 to calibrate the probe's stylus. Contained in this chapter Angle single surface measurement – macro O9821........................................................ 8-2 Angled web or pocket measurement – macro O9822...................................................... 8-5 3-point bore or boss measurement – macro O9823 ........................................................ 8-9 Publication No. H-2000-6222 8-2 Vector measuring cycles Angle single surface measurement – macro O9821 NOTE: The probe must have recently been calibrated using the vector stylus ball radius macro O9804 (described in Chapter 6, “Calibration cycles”) before using this cycle. Do not use macro O9803 to calibrate the probe. NOTE: Angles in the range ±180° +Aa angles (counter-clockwise) Dd Y 90° Aa X 180° 0° -90° Figure 8.1 Measuring an angled surface Description This cycle measures a surface feature using one vectored measuring move along the X Y axis. Application Position the probe to the expected reference point of the feature and a suitable position in the Z axis with the probe and probe offset active. Run the cycle with suitable inputs as described. Format G65 P9821 Aa Dd [Ee Ff Hh Mm Qq Ss Tt Uu Vv Ww] where [ ] denote optional inputs Example: G65 P9821 A45.005 D50.005 E0.005 F0.8 H0.2 M0.2 Q10. S1. T20. U.5 V.5 W2. Publication No. H-2000-6222 Vector measuring cycles 8-3 Compulsory inputs Aa a = Direction of probe measurement measured from the X+ axis direction. Dd d = Nominal distance to the surface (radial). Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.4 in) in the X,Y axis. Ss s= The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). Publication No. H-2000-6222 8-4 Vector measuring cycles Example Angle single surface measurement 50.0 Y 45° X Figure 8.2 Measuring a single angled surface 2 1 1. T01M06 Select the probe. 3 2. G54X-40.Y20. Start position. 9 4 3. G43H1Z100. Activate offset 1, go to 100 mm 8 (3.94 in). 5 4. G65P9832 Spin the probe on (includes M19), or 7 M19 for spindle orientation. 6 5. G65P9810Z-8.F3000 Protected positioning move to start position. Z Y 6. G65P9821A45.D50.T10 Single surface measure. 7. G65P9810Z100. Protected positioning move. X 8. G65P9833 Spin the probe off (when applicable). Figure 8.3 Probe movements 9. G28Z100. Reference return. The tool radius offset (10) is updated by the error of surface position. Publication No. H-2000-6222 Vector measuring cycles 8-5 Angled web or pocket measurement – macro O9822 NOTE: The probe must have recently been calibrated using the vector stylus ball radius macro O9804 (described in Chapter 6, “Calibration cycles”) before using this cycle. Do not use macro O9803 to calibrate the probe. Aa Aa 180 0 A - a Dd Y+ Aa X+ NOTE: Angles in the range ±180° +Aa angles (counter-clockwise) Aa Figure 8.4 Measuring an angled web or pocket Description This cycle measures a web or pocket feature using two vectored measuring moves along the X Y axis. Application Position the probe to the expected centre line of the feature and a suitable position in the Z axis with the probe and probe offset active. Run the cycle with suitable inputs as described. Publication No. H-2000-6222 8-6 Vector measuring cycles Format G65 P9822 Aa Dd [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9822 Aa Dd Zz [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] where [ ] denote optional inputs Example: G65 P9822 A45.005 D50.005 Z50. E0.005 F0.8 H0.2 M0.2 Q10. R10. S1. T20. U.5 V.5 W2. Compulsory inputs Aa a = Angle of the surface to be measured from the X+ axis direction. Dd d = Nominal size of the feature. Zz z = The absolute Z axis position when measuring a web feature. If this is omitted a pocket cycle is assumed. Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Rr r = This is an incremental dimension that is used in external features, e.g. bosses and webs, to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). R-r -r = This is similar to Rr, except that the clearance is applied in the opposite direction to force an internal web cycle. Default value is 5 mm (0.200 in). Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated Publication No. H-2000-6222 Vector measuring cycles 8-7 Ww Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). Publication No. H-2000-6222 8-8 Vector measuring cycles Example Angle web measurement 50.0 -10 30° Figure 8.5 Measuring an angled web 1. T01M06 Select the probe. 2 1 2. G54X0Y0 Start position. 9 3 3. G43H1Z100.0 Activate offset 1, go to 4 100 mm (3.94 in). 8 5 4. G65 P9832 Spin the probe on (includes M19), or M19 for spindle 7 orientation. 6 5. G65P9810Z10.F3000 Protected positioning move. 6. G65P9822A30.D50.Z-10.S2 Measure a 50.0 mm (1.9685 in) wide web at 30 degrees. Z Y 7. G65P9810Z100. Protected positioning move. X 8. G65P9833 Spin the probe off (when applicable). Figure 8.6 Probe movements 9. G28Z100. Reference return Continue The feature centre line in the X axis is stored in the work offset S02 (G55). Publication No. H-2000-6222 Vector measuring cycles 8-9 3-point bore or boss measurement – macro O9823 NOTE: The probe must have recently been calibrated using the vector stylus ball radius macro O9804 (described in Chapter 6, “Calibration cycles”) before using this cycle. Do not use macro O9803 to calibrate the probe. 90° Bb Aa 180° 0° Cc Rr -90° Dd N OTE: Angles in the range ±180° +Aa angles (counter-clockwise) R-r Figure 8.7 3-point bore or boss measurement Description This cycle measures a bore or boss feature using three vectored measuring moves along the X Y axis. Application Position the probe to the expected centre line of the feature and a suitable position in the Z axis with the probe and probe offset active. Run the cycle with suitable inputs as described. Publication No. H-2000-6222 8-10 Vector measuring cycles Format G65 P9823 Aa Bb Cc Dd [Ee Ff Hh Mm Qq Rr Ss Tt Uu Vv Ww] or G65 P9823 Aa Bb Cc Dd Zz [Ee Ff Hh Mm Qq Rr Ss Tt Uu VvWw] where [ ] denote optional inputs Example: G65 P9823 A45.005 B150.0 C35.005 D50.005 Z50. E.005 F0.8 H0.2 M0.2 Q10. R10. S1. T20.U.5 V.5W2. Compulsory inputs Aa a = The first angle for vector measurement, measured from the X+ axis direction. Bb b = The second angle for vector measurement, measured from the X+ axis direction. Cc c = The third angle for vector measurement, measured from the X+ axis direction. Dd d = Nominal size of feature. Zz z = The absolute Z axis position, when measuring a boss feature. If this is omitted, a bore cycle is assumed. Optional inputs Hh h = The tolerance value of a feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Rr r = This is an incremental dimension that is used in external features, e.g. bosses and webs, to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). R-r -r = This is similar to Rr, except that the clearance is applied in the opposite direction to force an internal boss cycle. Default value is 5 mm (0.200 in). Publication No. H-2000-6222 Vector measuring cycles 8-11 Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = This is the tool offset number to be updated. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu, and Vv, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). Publication No. H-2000-6222 8-12 Vector measuring cycles Example 3-point bore measurement (referred datum) 1. T01M06 Select the probe. 2 1 2. G54X100.Y100. Start position. 3 3. G43H1Z100. Activate offset 1 go to 100 mm 9 (3.94 in). 4 4. G65 P9832 Spin the probe on (includes 8 M19), or M19 for spindle 7 5 orientation. 5. G65P9810Z-10.F3000 Protected positioning. 6 6. G65P9823D30.A30.B150.C-90. S2 Measure a 30.0 mm (1.181 in) diameter bore. Z 7. G65P9810Z100. Protected positioning move. Y 8. G65P9833 Spin the probe off (when X applicable). Figure 8.8 9. G28Z100. Reference return Probe movements Continue The error of centre line is referred to the datum point X0,Y0 and the revised X0,Y0 position is set in work offset 02 (G55). Publication No. H-2000-6222 Additional cycles 9-1 Chapter 9 Additional cycles The Inspection Plus software contains a number of macro cycles that cannot be categorised under the headings used in previous chapters of this manual (chapters 5 to 8 inclusive). This chapter describes how to use these cycles. Contained in this chapter 4th axis X measurement – macro O9817 ........................................................................ 9-2 4th axis Y measurement – macro O9818 ........................................................................ 9-5 Bore / boss on PCD measurement – macro O9819 ........................................................ 9-8 Stock allowance – macro O9820 ................................................................................... 9-11 Storing multi-stylus data – macro O9830....................................................................... 9-16 Loading multi-stylus data – macro O9831...................................................................... 9-19 Turning the probe on – macro O9832............................................................................ 9-22 Turning the probe off – macro O9833............................................................................ 9-23 Determining feature-to-feature data in the XY plane – macro O9834............................ 9-24 Determining feature-to-feature data in the Z plane – macro O9834 .............................. 9-29 Updating the SPC tool offset – macro O9835................................................................ 9-33 Optimising a probing cycle – macro O9836 ................................................................... 9-35 Angle measurement in the X or Y plane – macro O9843 .............................................. 9-38 Publication No. H-2000-6222 9-2 Additional cycles 4th axis X measurement – macro O9817 Xx NOTE: Angle correction to 4th axis + (positive) counter-clockwise - (negative) clockwise X0 (BO) Z+ Zz X+ Figure 9.1 4th axis X measurement Description The purpose of this macro is to find the slope of a surface between two points Z1 and Z2 and make the necessary correction by indexing a ‘rotary axis’ to compensate. It also updates a ‘work zero point’ for that axis if required. Application The 4th axis must be positioned to the expected angular position of the feature (i.e. surface normal to the Z axis). The cycle finds the error of surface position, and then adjusts the axis work offset or checks a tolerance. NOTE: It is normally necessary on most machines to re-state the work offset and move to the angular position after the cycle to make the new work offset active. Format G65 P9817 Xx Zz [Qq Bb Ss Ww] where [ ] denote optional inputs. Example: G65 P9817 X100. Z50. Q10. B2. S1. W2. Publication No. H-2000-6222 Additional cycles 9-3 Compulsory inputs Xx x = The X axis distance between Z1 and Z2 measurement positions. Zz z = The Z axis expected surface position. Optional inputs Bb b = Set a tolerance on the angular position of the feature. It is equal to half the total tolerances, e.g. component dimension 45 degrees (±0.25 degrees) the 4th axis would be positioned to 45 degrees and B.25 tolerance. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 10 mm (0.4 in). Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. Outputs #193 will show (Z1 - Z2) value #194 will show angle correction value #189 will show 4th axis measured position NOTE: Different machines and application may require the 4th axis system variable number to be changed. It will be achieved by editing macro O9817 when the macro is installed to suit your machine. Edit as follows: #3 = 4 (4th axis number) change axis number as required. Publication No. H-2000-6222 9-4 Additional cycles Axis direction change Edit as follows: #4 = 1 (1 = clockwise, and -1 = counter-clockwise) change as required. Example Set the 4th axis to a milled flat 1. T01M06 Select the probe. 9 1 2. G43H1Z200. Activate offset 1, go to 100 mm 2 (3.94 in). 3 3. G65P9832 Spin the probe on (includes 8 M19), or M19 for spindle 7 5 orientation. O BO 45 4. G0B45. Position 4th axis to 45 degrees. 6 5. G65P9810X0Y0Z20.F3000 Position 10 mm (0.394 in) above the surface. 6. G65P9817X50.Z10.B5. Measure at 50 mm (1.9685 in) centres, update G54 and set a 4 tolerance of 5 degrees. 7. G65P9810Z200. Protected positioning move. 8. G65P99833 Spin the probe off (when Z applicable). C B Y 9. G28Z200. Reference return. A X continue Figure 9.2 Probe movements Publication No. H-2000-6222 Additional cycles 9-5 4th axis Y measurement – macro O9818 Yy NOTE: Angle correction to 4th axis + (positive) counter-clockwise - (negative) clockwise Y0 (BO) Z+ Zz Y+ Figure 9.3 4th axis Y measurement Description The purpose of this macro is to find the slope of a surface between two points Z1 and Z2 and make the necessary correction by indexing a ‘rotary axis’ to compensate. It also updates a ‘work zero point’ for that axis if required. Application The 4th axis must be positioned to the expected angular position of the feature, i.e. surface normal to the Z axis. The cycle finds the error of surface position, and then adjusts the axis work offset or checks a tolerance. NOTE: It is normally necessary on most machines to re-state the work offset and move to the angular position after the cycle to make the new work offset active. Format G65 P9818 Yy Zz [Qq Bb Ss Ww] where [ ] denote optional inputs Example: G65 P9818 Y100. Z50. Q10. B2. S1. W2. Publication No. H-2000-6222 9-6 Additional cycles Compulsory inputs Yy y = The Y axis distance between Z1 and Z2 measurement positions. Zz z = The Z axis expected surface position. Optional inputs Bb b = Set a tolerance on the angular position of the feature. It is equal to half the total tolerances, e.g. component dimension 45 degrees ±.25 degrees the 4th axis would be positioned to 45 degrees and B.25 tolerance. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 10 mm (0.4 in). Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = External offset + error. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. Outputs #193 will show (Z1 - Z2) value #194 will show angle correction value #189 will show 4th axis measured position NOTE: Different machines and application may require the 4th axis system variable number to be changed. It is achieved by editing macro O9818 when the macro is installed to suit your machine. Edit as follows: #3 = 4 (4th axis number) change axis number as required. Publication No. H-2000-6222 Additional cycles 9-7 Axis direction change Edit as follows: #4 = 1 (1 = clockwise, and -1 = counter-clockwise) change as required. Example Set the 4th axis to a milled flat 1. T01M06 Select the probe. 2. G43H1Z200. Activate offset 1, go to 100 mm (3.94 in). 9 1 3. G65P9832 Spin the probe on (includes M19), or 2 M19 for spindle orientation. 8 3 4. G0A45. Position 4th axis to 45 degrees. 7 5. G65P9810X0Y0Z20.F3000 Position 10 mm (0.394 in) above the 5 O 45 surface. 6 AO 6. G65P9818Y50.Z10.S1.B5. Measure at 50 mm (1.9685 in) centres, update G54 and set a tolerance of 5 degrees. 7. G65P9810Z200. Protected positioning move. 4 8. G65P9833 Spin the probe off (when applicable). 9. G28Z200. Reference return. Continue Z Y X Figure 9.4 Probe movements Publication No. H-2000-6222 9-8 Additional cycles Bore / boss on PCD measurement – macro O9819 NOTE: Angles in the range ±180° +Aa angles (counter-clockwise) 90o Aa Kk Kk 180o o 0 Dd -90o Zz Zz Cc P.C.D. Figure 9.5 Bore / boss on PCD measurement Description The macro measures a series of bores or bosses on a pitch circle diameter (PCD). All probe moves occur automatically and return to the start position at the centre of the PCD. Application 1. The probe is positioned at the centre of the PCD above the component. The probe moves to all bore/boss features and measures each feature automatically. The probe then returns to the PCD centre at the end of the cycle. 2. The macro makes use of the bore/boss macro which is nested within the moves. This means that the macro nesting level is four deep, which means that this macro cannot be nested inside a customer macro. 3. If a “probe open” condition occurs during any of the moves between bore/boss features a path obstructed alarm occurs and the probe stays in position instead of returning to the start position as is usual. This is done for safety reasons because the return path to centre line of the PCD may be obstructed. Publication No. H-2000-6222 Additional cycles 9-9 Format Boss G65 P9819 Cc Dd Zz [Aa Bb Ee Hh Mm Qq Rr Uu Ww] or Bore G65 P9819 Cc Dd Kk [Aa Bb Ee Hh Mm Qq Rr Uu Ww] where [ ] denote optional inputs. Example: G65 P9819 C28.003 D50.005 K11. A45.005 B2. E0.005 H0.2 M0.2 Q10. R10. U.5 W2. Compulsory inputs Cc c = PCD. The pitch circle diameter of the bore/boss feature. Dd d = Diameter of the bore/boss. Kk k = Absolute Z axis position where the bore is to be measured. Zz z = Absolute Z axis position where the boss is to be measured. Optional inputs Aa a = Angle measured from the X axis to the first bore/boss feature. Default value = 0. Bb b = The number of bore/boss features on the PCD. Default value = 1. Hh h = The tolerance value of the bore/ boss dimension being measured. Mm m = The true position tolerance of the bore or boss. A cylindrical zone about the theoretical position. Qq q = The probe's overtravel distance for use when the default values are unsuitable. The probe then travels beyond the expected position when it searches for a surface. Default values are 4 mm (0.16 in) in the Z axis and 10 mm (0.394 in) in the X,Y axis. Rr r = This is an incremental dimension that is used in an external bore or boss to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). R-r -r = This is an incremental dimension that is used in an internal boss or web to give a radial clearance from the nominal target surface prior to a Z axis move. Default value is 5 mm (0.200 in). Publication No. H-2000-6222 9-10 Additional cycles Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee and Uu, see Chapter 3, “Optional inputs”. Outputs The feature measurements will be stored in variables #185 to #199 (see Chapter 4, “Variable outputs”). W2.0 Component number (incremented by 1). Feature number (set to 1). W1. Feature number (incremented by 1). The following data is output to the ‘on-line device’ (printer): Diameter of each bore/boss 1. XY absolute position of each feature. Angle position of each feature. PCD pitch circle diameter of each feature. 2 The feature number. 3. Error of size and position. Refer to the print macro details for the output format. Uu u = When the upper tolerance is exceeded. The macro continues to the end of the macro and print data is output for each feature. The “Upper Tolerance Exceeded” alarm occurs and #169 = 2 is set if #170 is set. Otherwise the flag #169 = 2 is set only. The program continues. Publication No. H-2000-6222 Additional cycles 9-11 Stock allowance – macro O9820 P2P(6 max) P1 Z P(6 max) P(6 max) X Y P1 P1 P2 P2 Figure 9.6 Measuring the stock allowance Description The cycle measures either an X or Y or Z surface at defined positions to establish the maximum and minimum stock condition of the surface. Application The probe should be positioned above the surface at the first measuring position. The cycle measures the surface at this position (P1). Additional points P2 to P6 maximum are measured as defined, depending on the number of sets of I, J, or K inputs. NOTES: 1. If setting a work offset, the surface position will be at the minimum measured position and the stock value is seen in #196. 2. If NOT setting a work offset the nominal position is assumed and the maximum and minimum values are seen in #194 and #195. Publication No. H-2000-6222 9-12 Additional cycles Format X surface measure NOTE: Successive pairs of Jj, Kk values G65 P9820 Xx Jj Kk [Ss Uu] must be in order for P2 to P6. or Y surface measure NOTE: Successive pairs of Ii, Kk values G65 P9820 Yy Ii Kk [Ss Uu] must be in order for P2 to P6. or Z surface measure NOTE: Successive pairs of Ii, Jj values G65 P9820 Zz Ii Jj [Ss Uu] must be in order for P2 to P6. where [ ] denote optional inputs Example: G65 P9820 X100. J10. K11. S1. U.5 (this shows one additional [JK] pair of values, i.e. P2) Compulsory inputs Xx or Yy x, y, z = The nominal surface position for stock allowance check. or Zz I1 (P2) to I5 (P6) i = X surface positions for P2 to P6 (maximum five additional positions). or J1 (P2) to J5 (P6) j = Y surface positions for P2 to P6 (maximum five additional positions). or K1 (P2) to K5 (P6) k = Z surface positions for P2 to P6 (maximum five additional positions). Publication No. H-2000-6222 Additional cycles 9-13 Optional inputs Uu u = The maximum stock allowance or upper tolerance (metal condition). 1. Uu input only. The upper tolerance metal condition, e.g., surface at 30.00 +2.0/-0.0 G65P9820Z30.0U2.0IiJj 2. Uu and Ss input. The maximum stock allowance. Ss s = The work offset number which will be set. This will be set to the minimum metal position #195. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Outputs 1. Uu input only “Upper tolerance exceeded” flag #198 will be set to 3 2. Uu and Ss input “Excess stock” flag #198 will be set to 6 #194 Maximum value (metal condition) #195 Minimum value (metal condition) #196 Variation (stock allowance) Uu INPUT ONLY Uu AND Ss INPUT Upp er tolerance exceeded Excess stock #195 Uu #195Uu #194 #196 #194 Nominal Work Nominal position offset set position to this position Figure 9.7 Outputs for the stock allowance cycle Publication No. H-2000-6222 9-14 Additional cycles Example 1 Checking a Z surface for stock variation P3 P2 P1 Z X50.0 Y50.0 Z0 P1 at X55 Y55 P2 at X155 Y55 P3 at X55 Y155 Figure 9.8 Checking a Z surface for stock variation Select the probe. G65P9810X55.Y55.Z20.F3000 Protected move to P1. G65P9820Z0I155.J55.I55.J155.U2. Measure at P1, P2, P3 and set a 2 mm (0.039 in) tolerance. continue machining Publication No. H-2000-6222 Additional cycles 9-15 Example 2 Checking an X surface and updating a work offset X20.0 Y50.0 P2 Z50.0 P1 X P1 at Y55. Z45. P2 at Y105. Z45. P3 P3 at Y180. Z45. Figure 9.9 Checking an X surface and updating a work offset Select the probe. G65P9810X40.Y55.Z45.F3000 Protected move to P1. G65P9820 X20.J105.K45.J180. K45.S2 Measure at P1, P2, P3 and set the X axis work offset G55 to the minimum stock position at program position X20. Retract, select tool and offset G55 for machining X surface at the new X20. surface position. Publication No. H-2000-6222 9-16 Additional cycles Storing multi-stylus data – macro O9830 This cycle stores the data following calibration. Probe 1 Probe 2 K2 K1 Calibration data Calibration data Figure 9.10 Storing multi-stylus data Description The macro is used to store probe stylus calibration data that has been established during the calibration cycles. It is stored in a spare set of macro variables. This macro must be used in conjunction with macro O9831 to recall relevant calibration data for each probe. Application Calibrate the stylus using macro O9802 and O9803. Run macro O9830 to store the calibration data #556 (556+0) to #559 (556+3). The values are recalled when macro O9831 is run. It is also possible to store calibration data for vector cycles, by the use of the optional input. Format G65 P9830 Kk Example: G65 P9830 K11. Publication No. H-2000-6222 Additional cycles 9-17 Compulsory input Kk k = The multi-stylus probe number for data storage. Active calibration data Store location XRAD YRAD XOFF YOFF XRAD YRAD XOFF YOFF K1 #556 #557 #558 #559 #574 #575 #576 #577 K2 #556 #557 #558 #559 #578 #579 #580 #581 For vector calibration data storage #556 to #559 are stored as shown above, plus all the vector radii as shown below. Buffer calibration data Store location RAD RAD RAD RAD K11 #566 #567 #568 #569 #582 #583 #584 #585 #570 #571 #572 #573 #586 #587 #588 #589 K12 #566 #567 #568 #569 #590 #591 #592 #593 #570 #571 #572 #573 #594 #595 #596 #597 Publication No. H-2000-6222 9-18 Additional cycles Example Multi-stylus store K1 O0003 G90G80G40G0 Preparatory codes for the machine. G54X0Y0 Start position (X, Y, Z values must be set in the work offset) G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). G65P9832 Spin the probe on (includes M19), or M19 for spindle orientation. G65P9810Z-5.F3000 Protected positioning move for Z. G65P9803D50.001 Calibrate in a reference feature (ring gauge). G65P9830K1 Store calibration values for multi-stylus K1. G65P9810Z100. Protected positioning move. G65P9833 Spin the probe off (when applicable) G28Z100. Reference return. H00 Cancel offset. M30 End of program Publication No. H-2000-6222 Additional cycles 9-19 Loading multi-stylus data – macro O9831 This cycle recalls the calibration data. Probe 1 Probe 2 K2 K1 Calibration data Calibration data Figure 9.11 Recalling multi-stylus data Description This macro is used in conjunction with O9830. It is used to recall stored calibration data to the active calibration variable range prior to using a particular probe stylus configuration. Application The program must be run immediately before any measuring cycle to select the correct probe calibration data. The Kk input determines the data to be recalled. Format G65 P9831 Kk Example: G65 P9831 K11. Publication No. H-2000-6222 9-20 Additional cycles Compulsory input Kk k = The multi-stylus probe number for data recall. The Kk input number should always be the same as that used to store the data using O9830 for a given stylus. Active calibration data Store location XRAD YRAD XOFF YOFF XRAD YRAD XOFF YOFF K1 #556 #557 #558 #559 #574 #575 #576 #577 K2 #556 #557 #558 #559 #578 #579 #580 #581 For vector calibration data storage #556 to #559 are stored as shown above, plus all the vector radii as shown below. Buffer calibration data Store location RAD RAD RAD RAD K11 #566 #567 #568 #569 #582 #583 #584 #585 #570 #571 #572 #573 #586 #587 #588 #589 K12 #566 #567 #568 #569 #590 #591 #592 #593 #570 #571 #572 #573 #594 #595 #596 #597 Publication No. H-2000-6222 Additional cycles 9-21 Example Multi-stylus load K1 and K2 T01M06 Select the probe. G54X100.Y100. Start position. G43H1Z100. Activate offset 1, go to 100 mm (3.94 in). G65P9832 Turn the probe on (includes M19), or M19 for spindle orientation. G65P9810Z-10.F3000 Protected positioning move. G65P9831K1 Load calibration values for multi-stylus K1. G65P9814D30.S2 Measure a 30.0 mm (1.181 in) diameter bore. G65P9810Z10. Protected positioning move. G65P9810X350. Protected positioning move. G43H2Z-10. Activate offset 2. G65P9831K2 Load calibration values for multi-stylus K2. G65P9814D130.S2 Measure a 130.0 mm (5.12 in) diameter bore. G65P9810Z100. Protected positioning move. G65P9833 Turn the probe off (when applicable). G28Z100. Reference return. continue Publication No. H-2000-6222 9-22 Additional cycles Turning the probe on – macro O9832 Description This macro is used to turn the probe on prior to it being used. The probe is loaded into the spindle and moved to a safe start plane, where the above format is used to activate the probe. In the event of a start-up failure, there is a loop in the software which tries to activate the probe up to four times. An alarm results if the probe does not activate. It should be noted that a small automatic Z axis movement takes place within the macro to test if the probe is active. NOTE: The probe tool offset must be active. Format G65P9832 Example G43H20Z100. Apply a tool offset and move to a safe plane. G65P9832 Turn the probe on (includes M19), or M19 for spindle orientation. G65P9810X----Y----F---- Move to a gauging position. Publication No. H-2000-6222 Additional cycles 9-23 Turning the probe off – macro O9833 Description This macro is used to turn the probe off prior to it being used. The probe is retracted to a safe start plane, where the above format is used to switch the probe off prior to a tool change. There is a loop in the software, which will tries to de-activate the probe up to four times. An alarm results if the probe does not switch off. It should be noted that a small automatic Z axis movement takes place within the macro to test if the probe is active. This means that the G28 reference return must be done following this macro, otherwise the G28 position is not effective. NOTE: The probe tool offset must be active. Format G65P9833 Example G65P9810Z100. Retract to a safe plane with the tool offset still active. G65P9833 Turn the probe off. G91 G28Z0 Retract continue Publication No. H-2000-6222 9-24 Additional cycles Determining feature-to-feature data in the XY plane – macro O9834 NOTE: Angles in the range ±180° +Aa angles (counter-clockwise) Dd P2 Yy Aa P1 Xx Figure 9.12 Determining feature-to-feature data in the XY plane Description This is a no-movement macro that is used after two measuring cycles to determine feature-to-feature data. Application Data for P1 and P2 must already be stored in variables #180 to #184, and #185 to #197 for P2, by running suitable measuring cycles. NOTE: The order P1 and P2 is important, because the data calculated is that of P2 with respect to P1. Values for P1 are obtained by programming G65 P9834 without any inputs after the first measuring cycle. Values for P2 are obtained by running a second measuring cycle – the feature-to-feature data is established by programming G65 P9834 with suitable inputs after the second measuring cycle. Publication No. H-2000-6222 Additional cycles 9-25 Format G65 P9834 Xx [Ee Ff Hh Mm Ss Tt Uu Vv Ww] or G65 P9834 Yy [Ee Ff Hh Mm Ss Tt Uu Vv Ww] or G65 P9834 Xx Yy [Bb Ee Hh Mm Ss Uu Ww] or G65 P9834 Aa Dd [Bb Ee Hh Mm Ss Uu Ww] or G65 P9834 (with no inputs). where [ ] denote optional inputs Examples G65 P9834 X100. E0.005 F0.8 H0.2 M0.2 S1.T20. U.5 V.5 W2. or G65 P9834 Y100. E0.005 F0.8 H0.2 M0.2 S1. T20. U.5 V.5 W2. or G65 P9834 X100. Y100. B2. E0.005 H0.2 M0.2 S1. U.5 W2. or G65 P9834 A45.005 D50.005 B2. E0.005 H0.2 M0.2 S1. U.5 W2. NOTES: 1. Updating a tool offset with T input is only possible if either O9811 or O9821 is used for P2 data. Otherwise an alarm (T INPUT NOT ALLOWED) results. 2. This cycle cannot be used in conjunction with the web/pocket cycle macro O9812. 3. Angles. The XY plane is with respect to the X+ axis direction. Use angles in the range ±180 degrees. 4. When G65P9834 (without any inputs) is used, then the following data is stored: from #185 to #180 #186 #181 #187 #182 #188 #183 #189 #184 Publication No. H-2000-6222 9-26 Additional cycles Compulsory inputs Xx x = The nominal incremental distance in the X axis. Yy y = The nominal incremental distance in the Y axis. Aa a = The angle of P2 with respect to P1 measured from the X+ axis (angles between ±180 degrees). Dd d = The minimum distance between P1 and P2. (No inputs) This is used to store output data of the last cycle for P1 data. Optional inputs Bb b = The angle tolerance of the surface, e.g. 30 degrees ±1 degree. Hh h = The tolerance value of the feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = The tool offset number to be updated. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu and Vv, see Chapter 3, “Optional inputs”. Publication No. H-2000-6222 Additional cycles 9-27 Example 1 Measuring the incremental distance between two holes 1 2 1. G65P9810X30.Y50.F3000 Protected positioning move. 3 7 8 2. G65P9810Z-10. Protected positioning move. 6 3. G65P9814D20. P1 20 mm (0.787 in) bore. 9 and 10 4. G65P9834 Store data. 4 and 5 Z 5. G65P9810Z10. Protected positioning move. Y 6. G65P9810X80.Y78.867 Move to new position. X Figure 9.13 7. G65P9810Z-10. Protected positioning move. Probe movements 8. G65P9814D30. P2 30 mm (1.181 in) bore. And either this 9. G65P9834X50.Y28.867M.1 Incremental distance measure with 0.1 mm (0.0039 in) true position tolerance. Or this 9. G65P9834A30.D57.735M.1 Publication No. H-2000-6222 9-28 Additional cycles Example 2 Surface to bore measurement 1 1. G65P9810X10.Y50.F3000 Protected positioning move. 2. G65P9810Z-10. Protected positioning move. 2 3. G65P9811X0. P1 at X 0 mm (0 in) position. 4. G65P9834 Store data. 8 and 9 6 5. G65P9810Z10. Protected positioning move. 7 5 6. G65P9810X-50. Move to new position. 7. G65P9810Z-10. Protected positioning move. 3 and 4 Z 8. G65P9814D20.5 P2 20.5 mm (0.807 in) bore. Y 9. G65P9834X-50.H.2 Measure distance 50 mm (-1.97 in). X Figure 9.14 Probe movemen ts Publication No. H-2000-6222 Additional cycles 9-29 Determining feature-to-feature data in the Z plane – macro O9834 NOTE: Angles in the range ±180° +Aa angles (counter-clockwise) P2 +Aa +Zz P1 Zz +Dd Zz Z+ Y+ P1 +Aa -Zz X+ P2 – D d Figure 9.15 Determining feature-to-feature data in the Z plane Description This is a no-movement macro that is used after two measuring cycles to determine feature-to-feature data. Application Data for P1 and P2 must already be stored in variables #180 to #184, and #185 to #197 for P2, by running suitable measuring cycles. NOTE: The order P1 and P2 is important, because the data calculated is that of P2 with respect to P1. Values for P1 are obtained by programming G65 P9834 without any inputs after the first measuring cycle. Values for P2 are obtained by running a second measuring cycle, and the feature-to- feature data is established by programming G65 P9834 with suitable inputs after the second measuring cycle. Publication No. H-2000-6222 9-30 Additional cycles Format G65 P9834 Zz [Ee Ff Hh Mm Ss Tt Uu Vv Ww] or G65 P9834 Aa Zz [Bb Ww] or G65 P9834 Dd Zz [Bb Ww] or G65 P9834 (with no inputs) where [ ] denote optional inputs Examples G65 P9834 Z50. E0.005 F0.8 H0.2 M0.2 S1.T20. U.5 V.5 W2. or G65 P9834 A45.005 Z50. B2. W2. or G65 P9834 D50.005 Z50. B2. W2. or 65 P9834 (with no inputs) NOTES: 1. Updating a tool offset with T input is only possible if O9811 is used for P2 data. Otherwise an alarm (T INPUT NOT ALLOWED) results. 2. Angles. These are with respect to the XY. Use angles in the range ±180 degrees. 4. When G65P9834 (without any inputs) is used, then the following data is stored: from #185 to #180 #186 #181 #187 #182 #188 #183 #189 #184 Inputs Aa Zz or Dd Zz inputs 1. +Dd/-Dd values should be used to indicate the direction of P2 with respect to P1. 2. +Aa angles (counter-clockwise). 3. Angles between ±180 degrees. Publication No. H-2000-6222 Additional cycles 9-31 Zz only input 1. +Zz/-Zz values should be used to indicate the direction of P2 with respect to P1. Compulsory inputs Aa a = The angle of P2 with respect to P1 measured from the XY plane (angles between ±180 degrees). Zz z = The nominal incremental distance in the Z axis. or Dd d = The exact distance between P1 and P2 measured in the XY plane. Zz z = The nominal incremental distance in the Z axis. or (No inputs) This is used to store output data of the last cycle for P1 data. Optional inputs Bb b = The angle tolerance of the surface, e.g. 30 degrees ±1 degree. Hh h = The tolerance value of the feature dimension being measured. Mm m = The true position tolerance of a feature. A cylindrical zone about the theoretical position. Ss s = The work offset number which will be set. The work offset number will be updated. S1 to S6 (G54 to G59) S0 (external work offset). S110 to S129 (G110 to G129) additional offsets option. S154.01 to S154.99 (G154 P1 to G154 P99) additional offsets option. New work offset = active work offset + error. New external offset = external offset + error. Tt t = The tool offset number to be updated. Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. For optional inputs Ee, Ff, Uu and Vv, see Chapter 3, “Optional inputs”. Publication No. H-2000-6222 9-32 Additional cycles Example 1 1 Measuring the incremental distance between two surfaces 2 1. G65P9810X30.Y50.F3000 Protected positioning move. 5 3 and 4 2. G65P9810Z30. Protected positioning move. 3. G65P9811Z20. P1 20 mm (0.787 in) surface. 6 and 7 4. G65P9834 Store data. 5. G65P9810X50. Move to new position. Z 6. G65P9811Z15. P2 15 mm (0.591 in) surface. Y X 7. G65P9834Z-5.H.1 Feature to feature at -5.0 mm Figure 9.16 (-0.197 in). Probe movements Example 2 Measuring an angled surface 1 1. G65P9810X30.Y50.F3000 Protected positioning move. 2 5 2. G65P9810Z30. Protected positioning move. 3 and 4 3. G65P9811Z20. P1 at 20 mm (0.787 in) position. 6 and 7 4. G65P9834 Store data. 5. G65P9810X77.474 Move to new position. Z Y 6. G65P9811Z10. P2 at 10 mm (0.394 in) position. X And either this 7. G65P9834D27.474Z-10.B.5 Measure slope -20 degrees (clockwise) angle tolerance ±5 Figure 9.17 Probe movements degrees. Or this 7. G65P9834A-20.Z-10.B.5 Publication No. H-2000-6222 Additional cycles 9-33 Updating the SPC tool offset – macro O9835 Cc Cc Run of measurements out of limit prior to correction. x x x x + x x x Vv x x x Nominal size Vv Figure 9.18 Updating the SPC tool offset Description This macro can be used in conjunction with measuring cycles to control tool offset updates. It offers the possibility of providing an update based on the average value of a sample of measurements. Application A measuring cycle should be run, but with no tool offset update (Tt input). A component tolerance (Hh input) can be used if required. The SPC macro should follow. An average value is accumulated until a specified continuous run of values are outside the control limit. At this point the tool offset is updated, based on the average value. IMPORTANT: Set the Mm store tool offsets to 0 on the offset page prior to use. Format G65P9835 Tt Mm [Vv Cc Ff Zz] where [ ] denote optional inputs Example: G65 P9835 T20. M0.2 V0.25 C4 F0.8 Z1. Publication No. H-2000-6222 9-34 Additional cycles Compulsory inputs Tt t = Tool offset number for updating. Mm m = Spare tool offset pair for storing average value and counter. m = Accumulated average value store location. m+1 = Counter store location. Optional inputs Cc c = Number of measurements out of tolerance before corrective action is taken (default = 3). Ff f = See Chapter 3, “Optional inputs”. Vv v = See Chapter 3, “Optional inputs”. Zz z = Flag for Z length offset update. A Z value needs to be input to force the length offset register to be updated, otherwise the radius register will be updated. NOTE: This input is only necessary when using type 'C' tool offset option. Example SPC tool offset updating From previous G65P9814D50.H.5 Measure bore to 0.5 mm (0.0197 in) tolerance. G65P9835T30.M31.V.1C4. T30 = Tool offset number for updating. M31. = Spare tool offsets pair (31 and 32). V.1 = Control limit. C4. = Run of measurements out of limit. Continues Publication No. H-2000-6222 Additional cycles 9-35 Optimising a probing cycle – macro O9836 (b) (a) (c) Z #562 x Qq a = Start a t 30 mm/min (1.181 in/min) b = #169*.6 feedrate c = Maxim um feedrate Figure 9.19 Optimising a probing cycle NOTE: For small and medium machines the default values for feedrate and back-off distance are adequate. Therefore it is not essential to run this macro in every case. Description This macro is used to establish the optimum maximum feedrate and back-off distance values for the probing cycles. Application 1. The probe should be made active. At this stage the turn-on macro for the optical probe may not be functioning. Therefore, use the MDI mode and turn the probe by using the appropriate M-code. 2. Position the probe stylus within 2 mm (0.08 in) of the surface. Call this macro within a small program, and run the cycle. The probe moves towards the Z surface at 30 mm/min. (1.2 in). The cycle continues to retract and find the surface several times to establish the optimum values. At the end, the cycle returns to the start position. Publication No. H-2000-6222 9-36 Additional cycles NOTE: The repeat surface finding moves get progressively faster until the maximum overtravel is reached. Also, the retract position off the surface increases. It is important, therefore, that you allow for adequate Z axis movement, e.g. 60 mm (2.4 in). The macro ends with a macro alarm message: MESSAGE 75 (#168=BMCF DIST AND #169=FAST FEED) These values are recommended values. They are not automatically installed into the active variables. Install values 1. The fast feed value in #169 must be loaded into the setting macro O9724. See Appendix C, “Settings macro details” for details. 2. The back-off distance in #168 must be transferred into variable #562. This is possible in ‘manual data input mode’. The variable is to be found on the common retained variable page. Format G65 P9836 Qq Example: G65 P9836 Q10. Optional input Qq q = The maximum overtravel for the probe. Default value is 4 mm (0.16 in). Diagnostic alarms See Chapter 10, “Macro alarms” for details. NOTE: Feedrates. All the feedrates within the software are related, and are dependent on the fast feedrate #169 value, with the exception of the gauging move. This is always at 100 mm/min (3.94 in/min). It should also be noted that the back-off distance #562 can be affected by changing the feedrate #169. Running this macro will establish compatible setting data. Publication No. H-2000-6222 Additional cycles 9-37 Feedrates Feedrates are internally calculated as shown: Basic move macro O9726 Z axis fast approach #169*.6 (3000 mm/min [120 in/min.] standard). XY axis fast approach #169*.6 (3000 mm/min [120 in/min.] standard). Gauge move 100 mm/min. (3.94 in/min) all axes. All other feedrates Z axis positioning #169*.6 (3000 mm/min. [120 in/min.] standard). XY axis positioning #169 (5000 mm/min. [200 in/min.] standard). Example Write a small program to run this macro. Position the probe approximately 2 mm (0.08 in) above a surface, with the probe active. % O5036 G40G80G90 Preparatory codes for the machine. H00 Make tool offset zero G65P9836Q6.0 Optimise for 6 mm (0.24 in) overtravel M30 % Publication No. H-2000-6222 9-38 Additional cycles Angle measurement in the X or Y plane – macro O9843 Dd NOTE: Aa +ve angles (counter-clockwise) Aa Dd X+ (AO) Y+ Yy X+ Xx Figure 9.20 Measuring an angled surface in the X or Y plane Description This cycle measures an X axis or Y axis surface at two positions to establish the angular position of the surface. Application The probe stylus must be positioned adjacent to the surface and at the required Z axis position to provide a suitable start position. The cycle makes two measurements, symmetrically about the start position, to establish the surface angle. Format G65 P9843 Xx Dd [Aa Bb Qq Ww] or G65 P9843 Yy Dd [Aa Bb Qq Ww] where [ ] denote optional inputs Example: G65 P9843 X50. D30. A45. H.2 Q15. W1. Publication No. H-2000-6222 Additional cycles 9-39 Compulsory inputs Dd d = The distance moved parallel to the X axis or Y axis between the two measuring positions. Xx x = The mid-point surface position of the surface. An Xx input results in a cycle measuring in the X axis direction. Yy y = The mid-point surface position of the surface. A Yy input results in a cycle measuring in the Y axis direction. NOTE: Do not mix the Xx and Yy inputs. Optional inputs Aa a = The nominal angle of the surface measured from the X+ axis direction positive angles (counter-clockwise). Specify angles between ±90 degrees of the default value. Defaults: X axis measuring 90 degrees. Y axis measuring 0 degrees. Bb b = The angle tolerance of the surface, e.g., 30 degrees ±1 degrees. Inputs A30.B1. Qq q = The probe move overtravel distance. Default value is 10 mm (0.394 in). Ww w = Print data 1. = Increment the feature number only. 2. = Increment the component number, and reset the feature number. Outputs #189 The surface angle measured from the X+ direction. #193 The measured height difference. #194 The surface angle error. Alarms Refer to Chapter 10, “Macro alarm list” for details of the macro alarms. Publication No. H-2000-6222 9-40 Additional cycles Example 30.0 Y+ O 45 X+ Y30.0 X30.0 Figure 9.21 Example of an angled surface measurement G65P9810 X30.Y50.Z100.F3000 Protected positioning move. G65P9810 Z-15. Protected move to start position. G65P9843Y30.D30.A45. Angle measure. G65P9810 Z100. Retract to a safe position. continue G17 G68G90X0Y0 R[#189] Rotate co-ordinate system by the angle. Continue machining program NOTE: The Renishaw probe cycles cannot be used while co-ordinate rotation is in force, i.e. cancel code G69. Publication No. H-2000-6222 Macro alarms 10-1 Chapter 10 Macro alarms When an error occurs during use of the Inspection Plus software, an alarm number or message is generated. This will be displayed on the screen of the controller. Contained in this chapter General alarms............................................................................................................... 10-2 Optimisation macro only (O9836) alarms....................................................................... 10-5 Publication No. H-2000-6222 10-2 Macro alarms General alarms Format #198 flag 3006 = 1(OUT OF TOL) Updates the offset if 1 1(OUT OF POS) the cycle start button is 2 1(ANGLE OUT OF TOL) pressed to continue. 4 1(DIA OFFSET TOO LARGE) 5 1(UPPER TOL EXCEEDED) No offset update if the 3 1(EXCESS STOCK) cycle start button is 6 pressed to continue. 1(PROBE SWITCH OFF FAILURE) Turn-off macro O9833 Action Check the following: The turn-off cycle may fail if the spindle speed of S500 is not achieved. Check that the spindle speed override is not active. Possible faulty probe. Cycle start to continue. Format #3000 = 101(PROBE START UP FAILURE) Turn-on macro O9832 Action Check the following: The turn-on cycle may fail if the spindle speed of S500 is not achieved. Check that the spindle speed override is not active. Possible faulty probe. This is a reset condition. Edit the program and start again from a safe start position. Publication No. H-2000-6222 Macro alarms 10-3 Format #3000 = 91 (MESSAGE) 91 (FORMAT ERROR) 91 (A INPUT MISSING) 91 (B INPUT MISSING) 91 (C INPUT MISSING) 91 (D INPUT MISSING) 91 (I INPUT MISSING) 91 (J INPUT MISSING) 91 (K INPUT MISSING) 91 (X INPUT MISSING) 91 (Y INPUT MISSING) 91 (Z INPUT MISSING) 91 (XYZ INPUT MISSING) 91 (DATA #180 TO #189 MISSING) 91 (X0 INPUT NOT ALLOWED) 91 (Y0 INPUT NOT ALLOWED) 91 (H INPUT NOT ALLOWED) 91 (T INPUT NOT ALLOWED) 91 (IJK INPUTS 5 MAX) 91 (XY INPUT MIXED) 91 (XY INPUT MIXED) 91 (ZK INPUT MIXED) 91 (SH INPUT MIXED) 91 (ST INPUT MIXED) 91 (TM INPUT MIXED) 91 (XYZ INPUT MIXED) 91 (K INPUT OUT OF RANGE) Action Edit the program. This is a reset condition. Edit the program and start again from a safe start position. Publication No. H-2000-6222 10-4 Macro alarms Format #3000 = 86(PATH OBSTRUCTED) protected positioning cycle only. Action Edit the program. This is a reset condition. Clear the obstruction and start again from a safe position. Format #3000 = 88(NO FEED RATE) protected positioning cycle only Action Edit the program. This is a reset condition. Insert the F___ code input, and start again from a safe position. Format #3000 = 89(NO TOOL LENGTH ACTIVE) Action Edit the program. This is a reset condition. G43 or G44 must be active before the cycle is called. Edit and start again from a safe position. Format #3000 = 92(PROBE OPEN) This alarm occurs if the probe is already triggered before a move. Action Clear the fault. This is a reset condition. Clear the fault and start again from a safe start position. The stylus may be in contact with a surface, or the probe has failed to reseat. This could be due to swarf trapped around the probe eyelid. Publication No. H-2000-6222 Macro alarms 10-5 Format #3000 = 93(PROBE FAIL) This alarm occurs if the probe did not trigger during the move. Action Edit the program. This is a reset condition. Edit the program and start again from a safe start position. The surface was not found or the probe has failed. Optimisation macro only (O9836) alarms Format #3000 = 72(SKIP SIGNAL ALREADY ACTIVE) optimisation macro only. This indicates that the machine skip signal is high prior to the probe move. Action Check that the probe is active and that the interface is not in error. Check wiring. Check that the interface output relay is configured correctly, i.e. N/C or N/O. Is the stylus in contact with a surface? Is there a possible reseat problem? Clear the fault. Format #3000 = 73(NO SKIP SIGNAL DURING MOVE) optimisation macro only. The skip signal was not activated during the move. Action Check the wiring. Check the probe's operation and interface LED outputs to confirm when the stylus is manually deflected; also relay output voltage to skip when the probe is triggered. Edit the program. Publication No. H-2000-6222 10-6 Macro alarms Format #3000 = 74(H00 CODE TOOL LENGTH NOT ACTIVE) optimisation macro only. The tool length offset must be set to zero by programming ‘H00’ prior to calling the macro. This permits the safe operation of jogging the stylus into a start position before running the macro. Action Edit the program. Format #3000 = 75(#168=BMCF DIST AND #169=FAST FEED) optimisation macro only. This is the end of the optimisation cycle. The values in #168 and #169 can be installed (see “Optimising a probing cycle - macro O9836” in Chapter 9, “Additional cycles” for details). Action Install setting values. Publication No. H-2000-6222 Example job A-1 Appendix A Example job Contained in this appendix Introduction ......................................................................................................................A-2 Probe operations..............................................................................................................A-3 Publication No. H-2000-6222 A-2 Example job Introduction The component shown in Figure A.1 is to be machined on two faces by rotating the component about the machine A axis on the 4th axis unit. o Machined0 lower left face padX+ Y+ 'A' axis 270o face Motorised arm base Z Fixture Y X Figure A.1 Motorised arm base – general view The following probe operations are carried out: The probe is used initially on the 0 degree face to level up the component using an A axis work offset shift. The component datum is then set in the X, Y, and Z axis for machining. During machining of this face, the side face of the lower left pad is machined as a datum for the 270 degree face machining (Ref. Y axis datum). The probe is also used on the 270 degree face to set the Y, Z axis component datum. Nominal work offset data is entered in G54 and G55 before the machining operation. Publication No. H-2000-6222 Example job A-3 Probe operations % O5866 (M-2116-0031-01-D) (MOTORISED ARM-BASE) (TAPE NO - T5866) (*) (PROBE TO FIND CENTRE) G17G94 G90G40G80 N10M00 (COMPONENT SET UP PROBING) (LOAD NOMINAL WORK OFFSETS) /T30 Select the probe /G91G28Z0A0 Retract /G28A0 Position A axis /G90 Absolute co-ordinates Refer to Figure A.2 for probe movements 1 to 18 18 6 17 1 NOTE 2 The machine Z axis is initially 'A' 16 3 aligned with the 0° face. 4 11 Z 10 Y 5 8 9 14 X 15 X+ Figure A.2 Probing operations on the 0-degree face Publication No. H-2000-6222 A-4 Example job 1. /G00G54X90.Y0. Rapid positioning 2. /G43G1H30Z100.F3000 Go to Z 100 mm (3.94 in), apply tool offset. 3. /G65P9832 Switch the probe on. 4. /G65P9810Z10.F3000 Protected move to start position. 5. /G65P9818Y79.Z0S1. Set G54 A axis on the top face. 6. /G0A0 Level to new A axis position. 7. /#5244=#5224 Transfer G54 A axis to G55 A axis work offset. 8. /G65P9810Z-28.F3000. Protected move to position. 9. /G65P9812Y69.S1. Set G54 Y centre. 10. /G65P9810X-35.Y0 Protected move to position. 11. /G65P9811X-44.S1. Set G54 X position. 12. /#5241=#5221 Transfer G54 X axis to G55 X axis work offset. 13. /G65P9810X0 Protected move to position. 14. /G65P9810Z-84. Protected move to position. 15. /G65P9811Z-94.S1. Set G54 Z position. 16. /G65P9810Z100. Protected move retract. 17. /G65P9833 Switch the probe off. 18. /G91G28Z0 /G90 /M01 Continue machining 0-degree face G0A-90. Index to 270 degree face. N210 (PROBE TO SET G55 Y Z) /M01 /T30 Select probe. /M09 /G91G28Z0 /G90 Publication No. H-2000-6222 Example job A-5 Refer to Figure A.3 for probe movements 20 to 30 21 NOTE 22 20 The machine Z axis is now 23 aligned with the 270° face. 25 24 30 'A' o26 29 27028 27 face Z X Y X+ Figure A.3 Probing operations on the 270-degree face 20. /G0G55X-38.0Y-74.0 Rapid positioning move 21. /G43G1H30Z100.F3000 Go to Z 100 mm (3.94 in), apply tool offset. 22. /G65P9832 Switch the probe on. 23. /G65P9810Z-5.F3000. Protected move to position. 24. /G65P9811Y-66.S2. Set G55 Y axis work offset. 25. /G65P9810X0Z10. Protected move to position. 26. /G65P9810Y-60. Protected moves to position. 27. /G65P9811Z0S2. Set G55 Z axis work offset. 28. /G65P9810Z100. Protected move retract. 29. /G65P9833 Switch the probe off. 30. /G91G28Z0 Retract /G90 /M01 Publication No. H-2000-6222 A-6 Example job Continue machining 270-degree face G91G28Z0 Z return G28X0Y0A0 X, Y, A return to start position. G90 N420 M01 M30 % Publication No. H-2000-6222 Features, cycles and limitation B-1 Appendix B Features, cycles and limitations of the Inspection Plus software Contained in this appendix Features of the Inspection Plus software.........................................................................B-2 Cycles ..............................................................................................................................B-3 Limitations........................................................................................................................B-3 Limitations when using vector cycles O9821, O9822 and O9823 ............................B-3 Use of 3-point bore/boss macro O9823 .........................................................B-4 Mathematical precision ....................................................................................................B-4 Effect of vector calibration data on results .......................................................................B-4 Publication No. H-2000-6222 B-2 Features, cycles and limitations of the Inspection Plus software Features of the Inspection Plus software Protected positioning. Measurement of internal and external features to determine both size and position. This includes: Obtaining a hardcopy printout of feature data. Applying tolerances to both size and position. Additional features for feedback of errors include: Experience values can be applied to the measured size. Percentage feedback of the error can be applied. Null band zone for no-tool offset update. SPC (statistical process control) feedback based on average value. Calculation of feature-to-feature data. Measurement of external and internal corners for corner surfaces which may not be parallel to an axis. Calibration of multiple stylii. 4th axis datum setting and tolerancing. Angular measurement of features. Software option to turn off the tolerance alarms and provide a flag-only alarm. Suitable for FMS and unmanned applications. Built in protection for stylus collision and false trigger protection for all cycles. Diagnostic and format error checking routines for all cycles. Publication No. H-2000-6222 Features, cycles and limitation B-3 Cycles Protected positioning. Measurement: XYZ single surface. Web / pocket. Bore / boss (four measuring points). Internal and external corner find. Vectored measurement: 3-point bore boss. Web / pocket. Single surface. Additional macros: 4th axis measurement. Bore / boss on a PCD. Stock allowance. Multi-stylus calibration. XY plane angle measurement. Limitations The probe cycles will not run if ‘mirror image’ is active. The probe cycles will not run if ‘co-ordinate rotation’ is active. Consider macro variable availability. Limitations when using vector cycles O9821, O9822 and O9823 Vectored cycles involve the mathematical operation of squared values. This can lead to precision errors if large values are used. The following factors must be considered: Publication No. H-2000-6222 B-4 Features, cycles and limitations of the Inspection Plus software Use of 3-point bore/boss macro O9823 The macro may be used to establish the centre and diameter of a bore or external feature. There is however a practical limitation to the use of the macro. It is advisable to use the largest distance between contacts, that is practical. The minimum conditions to give reliable data are as follows: 1. 168 degrees total span. 2. 48 degrees between any two points. The software does not check the minimum condition inputs. The accuracy of the result deteriorates if the minimum conditions are not followed. Mathematical precision The mathematical precision of the controller is a limiting factor if large values are used. The controller works within an accuracy of eight significant figures. Because of the mathematical operations concerned, an error may accumulate if large values for probing positions about the centre are used for calculation. It is suggested that, at this moment, X Y coordinate values of ±300.00 mm (30.000 in) from the feature centre are not exceeded for any position around a bore, to retain a resultant resolution of better than 0.01 mm (0.001 in). Effect of vector calibration data on results The vector calibration cycle establishes true calibration data at each 30 degree increment. A small error due to the probe's trigger characteristics may occur at intermediate angles between the 30 degree calibration points. However this error is small for standard machine tool probes with standard styli. NOTE: For better accuracy, always use the standard bore boss cycle (O9814) where possible. Publication No. H-2000-6222 Settings macro details C-1 Appendix C Settings macro details Contained in this appendix Macro G65P9724.............................................................................................................C-2 Publication No. H-2000-6222 C-2 Settings macro details Macro G65P9724 This macro is called at the beginning of all top level macros to establish the necessary modal information. The following data may be adjusted to suit during the installation by editing this macro. The following values are supplied as standard: #170 = 1 (SELECT OPTIONS) (see the table below) #173 = .05 (POSITION ZONE MM) This is the zone at either the start or end of the block in which the cycle is aborted with either Probe Open or Probe Fail. #169 = 5000 (FAST FEED MM) The fast feed rate of the cycles can be #169 = 200 (FAST FEED INCH) adjusted by this variable to suit the machine characteristics and should be optimised. NOTES: 1. The X, Y and Z axis P9726 basic move macro fast feedrate is #169*.6, i.e. 3 metres/min as standard. 2. All Z axis positioning moves are also #169*.6, i.e. 3 metres/min as standard. 3. All XY axis positioning moves are #169 value i.e. 5 metres/min as standard. Setting conditions for variable #170 Radius/diameter tool offset type Tolerance alarm method Setting value Radius type Flag and alarms #170=3 Diameter type Flag and alarms #170=19 Radius type Flag only #170=7 Diameter type Flag only #170=23 It is expected that the settings to enable ‘Flag only alarms’ will suit FMS machining cells where the requirement is to run unmanned. The process error flag #198 will be set and it should be monitored after relevant probe cycles for corrective action. Publication No. H-2000-6222 Settings macro details C-3 Example G65 P9812 X30.H.2 Set tolerance on measured size IF[#198EQ1] GOTO999 Test for out of tolerance continue part program GOTO1000 N999 G65P5001 Pallet change. This changes the pallet to select the next component for machining (details are machine dependent). GOTO1 Go to start of program N1000 M30 Publication No. H-2000-6222 C-4 Settings macro details This page intentionally left blank. Publication No. H-2000-6222 Tolerances D-1 Appendix D Tolerances Contained in this appendix Tolerances .......................................................................................................................D-2 True position tolerances...................................................................................................D-3 Publication No. H-2000-6222 D-2 Tolerances Tolerances Uu, Hh and Vv apply to size and tool offset updates only. + e d c Uu Hh tol Vv input b a _ a = Nominal size b = Null band. This is the tolerance zone where no tool offset adjustment occurs. c = Area where the Ff input is effective in percentage feedback. F (0 to 1) gives 0% to 100% feedback to the tool offset. d = Hh “Out of Tolerance alarm” occurs. The tolerance value is that which is applied to the size of a feature. e = Uu upper tolerance limit. If this value is exceeded there is no tool offset or work offset updated and the cycle is stopped with an alarm. This tolerance applies to both size and position where applicable. Figure D.1 Size and tool offset update tolerances Also see SPC macro O9835 (see Chapter 9, “Additional cycles”) which can be used as a modified method for the feedback of tool offset corrections. Use this instead of Ff. Publication No. H-2000-6222 Tolerances D-3 True position tolerances For a true position tolerance (Mm input), see Figure D.2 below. Axis of datum Possible axes True position Tol. 0.1 (Mm input) Figure D.2 Cylinders centred on true positions Publication No. H-2000-6222 D-4 Tolerances This page intentionally left blank. Publication No. H-2000-6222 Experience values Ee E-1 Appendix E Experience values Ee Contained in this appendix Experience values Ee ......................................................................................................E-2 Reason for using this option ............................................................................................E-2 Publication No. H-2000-6222 E-2 Experience values Ee Experience values Ee The measured size can be adjusted by an amount stored in a spare tool offset. Example Measure a 40 mm diameter and update tool offset 20 G65P9814 D40. T20 E21 An experience value stored in tool offset 21 will be applied to the measured size. NOTE: The experience value is always added to the measured size. Also refer to Appendix F, “Additional spare tool offsets”. Reason for using this option Component clamping forces in some applications can influence the measured size. Therefore, an adjustment value to relate measurement to a traceable standard, such as a co-ordinate measuring machine, is desirable. Thermal effects can also be compensated by this means. Publication No. H-2000-6222 Additional spare tool offsets F-1 Appendix F Additional spare tool offsets Contained in this appendix Additional spare tool offsets............................................................................................. F-2 Publication No. H-2000-6222 F-2 Additional spare tool offsets Additional spare tool offsets The range of tool offsets available is extended with the Type C tool offset installed on the machine. Each tool offset is actually four registers. These are tool length geometry and wear, plus tool diameter / radius geometry and wear. There may be limitations on the maximum values allowable in the wear offsets set by the OEM. In practice, it may only be possible to use the geometry registers. These can be addressed in the macro call line as follows: Tool length geometry offsets E1 to E100 Tool diameter / radius geometry offsets E401 to E500 From the figures you can see that 400 can be added to the tool offset number to address the additional range of registers. These additional tool offset registers can safely be used for both 'Ee' experience values and also with the SPC macro (O9835) 'Mm' input provided. The tool offset number is not used as a normal tool offset location. Publication No. H-2000-6222 Printing a macro output G-1 Appendix G Printing a macro output Contained in this appendix Example of printing a macro output ................................................................................ G-2 Publication No. H-2000-6222 G-2 Printing a macro output Example of printing a macro output --------------------------------------------------------------------- COMPONENT NO 31 FEATURE NO 1 --------------------------------------------------------------------- POSN R79.0569 ACTUAL 79.0012 TOL TP 0.2000 DEV -0.0557 POSN X-45.0000 ACTUAL -45.1525 TOL TP 0.2000 DEV -0.1525 POSN Y-65.0000 ACTUAL -64.8263 TOL TP 0.2000 DEV 0.1737 +++++OUT OF POS+++++ ERROR TP 0.1311 RADIAL ANG -124.6952 ACTUAL -124.8578 DEV -0.1626 --------------------------------------------------------------------- COMPONENT NO 31 FEATURE NO 2 --------------------------------------------------------------------- SIZE D71.0000 ACTUAL 71.9072 TOL 0.1000 DEV 0.9072 +++++OUT OF TOL+++++ ERROR 0.8072 POSN X-135.0000 ACTUAL -135.3279 DEV -0.3279 POSN Y-65.0000 ACTUAL -63.8201 DEV 1.1799 Publication No. H-2000-6222 Output flow (bore/boss and web/pocket cycles) H-1 Appendix H Output flow (bore/boss and web/pocket cycles) Contained in this appendix Output flow (bore/boss and web/pocket cycles) ..............................................................H-2 Publication No. H-2000-6222 H-2 Output flow (bore/boss and web/pocket cycles) Output flow (bore/boss and web/pocket cycles) Measure N10 Y If error flag N #199 NEO If U input If #199 Y If E input N If size NE 2 error Probe fail Size adjust If pos Y #3000 experience error N11 Output variables If H input N Flag #198=3 #185 to #199 Pro be Y open N N If W input If size If flag only #3000 error #170.4=1 Upper Print data to Flag #198=1 tolerance RS232 port exceeded #3006 N10 If flag only Y END #170.4=1 If size N error Out of tolerance #3006 #3000 alarms must reset machine #3006 cycle start to continue N13 Publication No. H-2000-6222 Output flow (bore/boss and web/pocket cycles) H-3 N1 3 N15 N19 N N N If M input If T input If S input N If p os If V band N Work offset error exceeded update Flag #198=2 YIf F input END Y Set F=1 If flag only #19 8=1 If p os N Update tool offset error error x F Out of position If radius N #30 06 too large N15 Flag #198=5 If flag only Y #170.4=1 Out of tolerance #3006 N19 Publication No. H-2000-6222 H-4 Output flow (bore/boss and web/pocket cycles) This page intentionally left blank. Publication No. H-2000-6222 Use of macro variables I-1 Appendix I Use of macro variables Contained in this appendix Local variables .................................................................................................................. I-2 Common variables ............................................................................................................ I-2 Common retained variables .............................................................................................. I-3 Publication No. H-2000-6222 I-2 Use of macro variables Local variables #1 to #32 These are used within each macro as required for calculation etc. Common variables #161 Base number for calibration. #166 Active tool length - calculated in macro O9723. #167 Modal feedrate value is used in the protected positioning macro (O9810). #168 Radius too large flag macro O9812, O9814, O9822, O9823 (also used for temporary ATAN store in macro O9731). #169 Fast feedrate value. This is set in macro O9724 at 5000 mm/min (200 in/min) default value. #170 Setting variable used in macro O9724. #171 Print, component number (6-digit) increment by 1, with each heading program #171 = 0 to reset. #172 Feature number (4-digit) increment by 1, with each print macro call program #172 = 0 to reset. #173 Start and end of block position zone normal setting 0.05 mm (0.002 in). If the skip position is within this zone, the cycle aborts, with a Probe Open or Probe Fail alarm. #174 Stored X skip position at the end of the basic move macro O9726 #175 Stored Y skip position at the end of the basic move macro O9726. #176 Stored Z skip position at the end of the basic move macro O9726. #177 X average skip position at the end of the X diameter move macro O9721. #178 Y average skip position at the end of the Y diameter move macro O9722. #179 Inch/metric multiplier (0.04/1.0) #180 to #184 Output data #180 to #184 is stored when the feature-to-feature macro O9834 is used. #185 to #199 See Chapter 4, “Variable outputs” for an output reference chart. Publication No. H-2000-6222 Use of macro variables I-3 Common retained variables The actual variables available are the limiting factor and depend on the base number used for adjusting the range of #500 variables used for data storage. The variable allocation described below assumes that the default base number of 556 (set in macro O9724) is being used. #556 (556 + 0) (XRAD) X calibration radius #557 (556 + 1) (YRAD) Y calibration radius #558 (556 + 2) (XOFF) X axis stylus offset #559 (556 + 3) (YOFF) Y axis stylus offset #560 (556 + 4) (Reserved for other software packages) #561 (556 + 5) (Reserved for other software packages) #562 (556 + 6) Basic move control factor. This is used to control the back-off distance in the basic move before the final gauge move. It should be fine tuned on installation to suit the machine. Refer to Figure I.1 for a diagrammatic representation. A default value of 0.2 is installed by the software. The actual factor should normally be between 0 and 1.0. Reduce the value to reduce the back-off distance. NOTE: This value can be found by using the optimisation macro O9836. The value must be set in the Settings macro O9724. (a) (c) (b) X #562 (556 + 6) (BMCF) X 1 2 3 Move 1 fast feed to find the surface a = Fast feed M ove 2 recover off the surface b = Gauge feed (100 mm/min) Move 3 gauge feed 100 mm/min (3.94 in/min) c = Return Figure I.1 Basic move control factor Publication No. H-2000-6222 I-4 Use of macro variables #563 (556 +7) (Reserved for other software packages) #564 (556 +8) (Reserved for other software packages) #565 (556 +9) Active vector radius used in macros O9821, O9822, O9823 #566 to #597 These are reserved for vector calibration data and multi- stylus storage as described below: #566 (30 degree) #567 (60 degree) #568 (120 degree) #569 (150 degree) Vector calibration data #570 (210 degree) #571 (240 degree) #572 (300 degree) #573 (330 degree) #574 to #577 Multi-stylus data K1 #578 to #581 Multi-stylus data K2 #582 to # 589 Vector multi-stylus data K11 #590 to #597 Vector multi-stylus data K12 Publication No. H-2000-6222 General probing applications J-1 Appendix J General probing applications Contained in this appendix Example 1 – Part identification ........................................................................................ J-2 Example 2 – Probe measure every nth component ......................................................... J-3 Publication No. H-2000-6222 J-2 General probing applications Example 1 – Part identification If a group of components can be identified by a single feature, a probe can be used to inspect that feature and decide which component is present. This is done by using data from the output chart following a measuring program. 74 A 72 70 C B Each part surface is known to be within ±0.5 Figure J.1 Part Identification G65 P9810Z84.F3000 Protected move to start position G65P9811Z70. Single surface measure (target C surface) IF[#187GT73.]GOTO100 If error greater than 73.0 go to N100 IF[#187GT71.]GOTO200 If error greater than 71.0 go to N200 IF[#187GT69.]GOTO300 If error greater than 69.0 go to N300 GOTO400 N100(PROGRAM TO MACHINE A) continue 'A’ component GOTO400 N200(PROGRAM TO MACHINE B) continue 'B' component GOTO400 N300(PROGRAM TO MACHINE C) continue 'C' component Publication No. H-2000-6222 General probing applications J-3 N400 M30 % Example 2 – Probe measure every nth component Often it is a requirement to probe every Nth component in the interests of reducing overall cycle time. The following programming method can be employed - O5000(PART PROGRAM) #120=0 Reset counter #121=5 Count limit N1 (START OF MACHINING) conventional part programming N32 (START OF PROBE ROUTINES) IF[#120LT#121]GOTO33 If counter less than 5 jump to N33 T01M06 (PART INSPECTION) Select inspection probe probing routines #120=0 Reset counter to zero N33 (CONTINUE MACHINING OR END) #120=#120+1 Increment counter rest of machining program M99P1 Return to N1 M30 % Publication No. H-2000-6222 J-4 General probing applications This page intentionally left blank. Publication No. H-2000-6222 One-touch measuring K-1 Appendix K One-touch measuring Contained in this appendix Introduction ......................................................................................................................K-2 Why use a one-touch probe cycle?..................................................................................K-2 Machine distortion............................................................................................................K-2 Comparing cycle times.....................................................................................................K-2 Installing the one-touch cycles.........................................................................................K-3 Macro edits.......................................................................................................................K-3 Measuring the feedrate .............................................................................................K-3 Stand-off and overtravel distance .............................................................................K-3 System operation .............................................................................................................K-4 Using standard skip ..................................................................................................K-4 Additional variables used..........................................................................................K-4 Approach feedrates...................................................................................................K-4 Back-off distance #562 (556 + 6)..............................................................................K-5 False trigger loop ......................................................................................................K-5 Acceleration and deceleration allowance .................................................................K-5 Q input..............................................................................................................................K-6 Measuring move detail .....................................................................................................K-6 One-touch measuring move logic ....................................................................................K-7 Publication No. H-2000-6222 K-2 One-touch measuring Introduction The Inspection Plus software package provides an optional one-touch measuring capability to supplement the standard two-touch cycles. The one-touch cycles are intended for use on machines with a fast probe trigger detection ability so that high measuring feedrates can be used. Why use a one-touch probe cycle? A one-touch cycle offers the benefit of reduced cycle times and fewer probe triggers per cycle. It can be used when the nominal surface position is known to within a small window of uncertainty. Machine distortion The machine is under stress during acceleration and deceleration and therefore the recorded trigger values may have errors depending on machine tool condition. Comparing cycle times A program was prepared to perform five surface measurements as follows: Start 50 mm above the ring gauge Measure a 50 mm bore at 5 mm deep (four cardinal points) Retract to 5 mm above, move over and make a Z measure on top of the ring gauge Retract to 50 mm and return to the centre Table K.1 shows cycle time comparisons only. Check for suitable measuring feed rates on your machine. Table K.1 Cycle time comparison Time in Time in Time in Time in seconds @ seconds @ seconds @ seconds @ 500 mm/min 120 mm/min 60 mm/min 30 mm/min Two-touch cycle - - - 27.6 One-touch cycle 0.5 18.0 18.5 20.0 22.4 Stand-off 1.0 18.2 19.8 22.2 27.2 distance 2.0 18.7 22.4 27.4 37.1 3.0 19.1 24.4 32.2 47.0 Publication No. H-2000-6222 One-touch measuring K-3 Installing the one-touch cycles NOTE: The new one-touch basic move macro O9726 is only compatible with the software supplied with this package. Previous versions are not compatible. Before installing the one-touch cycles, the standard two-touch cycles must already have been installed. The one-touch cycles file (401200885) contains a new one-touch macro O9726. This should be loaded once the existing two-touch macro O9726 has been deleted from memory. Macro edits Macro O9726, shown below, may be edited for measuring feed rate and stand- off/overtravel distance values: :9726(REN BASIC MEASURE -1T) #9=500*#179(EDIT MEAS FEED) ....* Feed - edit 500 value #28=#9/1000(EDIT ZONE) .... accel / deceleration zone #31=0 IF[#17NE#0]GOTO2 #17=3*#179(EDIT)....... * stand off - edit 3 value N2 NOTE: * denotes this value must be in millimetres Measuring the feedrate The default value is 500 mm/min (20 in/min). This may be changed by editing the macro; for example, if the servo delays are included in the results. Stand-off and overtravel distance The default value is 3 mm (0.12 in) in the X, Y and Z axes. Edit the macro to set a new default or, alternatively, use the ‘Q’ input to override the default value (see page K-6). Publication No. H-2000-6222 K-4 One-touch measuring System operation Refer to the chapters of this manual for a full description of the cycles and their use. Using standard skip Based on a typical 4 millisecond scan time of the PLC, the standard two-touch method uses a feedrate of 30 mm/min (1.18 in/min). This gives a measuring uncertainty of 0.002 mm (0.0001 in). Generally, the two-touch method is well suited to this situation because the back-off distance can be optimised to provide a short measuring move; for example, less than 0.5 mm (0.020 in). If the one-touch cycles are chosen, the stand-off distance should be kept small and higher feedrates used if accuracy of measuring is not critical. NOTE: Measuring uncertainty is related to the feedrate. Table K.2 Example using the 4 millisecond scan time allowance Feedrate Measuring uncertainty 30 mm/min 0.002 mm 60 mm/min 0.004 mm 120 mm/min 0.008 mm 500 mm/min 0.033 mm Additional variables used The following additional variables are used by this software: #174 This is used to store the X axis measured skip position. The value is set in macro O9726. #175 This is used to store the Y axis measured skip position. The value is set in macro O9726. #176 This is used to store the Z axis measured skip position. The value is set in macro O9726. Approach feedrates The feedrate for the approach to the stand-off position in macro O9726 is set at 3000 mm/min (120 in/min) in the X, Y and Z axes. Publication No. H-2000-6222 One-touch measuring K-5 Back-off distance #562 (556 + 6) This variable is not used in the one-touch cycles. False trigger loop At the end of the measuring move a false trigger test is made to see if the probe is triggered against a surface. If the probe has reseated, the measuring move continues. Four attempts are made before a “Probe open” alarm occurs. Acceleration and deceleration allowance To avoid the possibility of capturing bad data (see Machine distortion on page K-2), the one-touch basic move sets a checking zone dimension at the start and end of the measuring move. If the data captured is within these zones, a “Probe open” or “Probe fail” alarm is generated. The zone dimension is related to the feedrate and is currently set as follows: Zone dimension = measuring feedrate / 1000 (i.e. zone factor = 1000) NOTE: See Macro edits on page K-3 for details of setting the measuring feedrate. Table K.3 Example of zone allowance using default zone factor 1000 Feedrate Acceleration and deceleration allowance 30 mm/min 0.03 mm 60 mm/min 0.06 mm 120 mm/min 0.12 mm 500 mm/min 0.50 mm NOTE: The allowable measuring range is the Q stand-off distance + twice this zone value. These values will be suitable in most cases, but optimisation or adjustment may be required on some machines. A test program can be prepared to test the measuring accuracy as follows: 1. Set the measuring feed rate in macro O9726. 2. Set a large Q value (for example, 3 mm (0.12 in) or greater). Publication No. H-2000-6222 K-6 One-touch measuring 3. Prepare a test program to measure a surface. 4. Measure the surface, ensuring the trigger is in the constant velocity zone (i.e. middle of measuring move) and record the first measured value. 5. Make a small STEP adjustment to the programmed surface position (for example, 0.5 mm) and repeat the test, recording the total STEP dimension and the measured value. 6. Repeat step 5, making several STEP changes (in the same direction). You will see when the measured result deviates from the first recorded value. This is the point where measurement becomes affected by acceleration/deceleration. Calculate the acceleration/deceleration value: A = absolute (‘Q’ value - total STEP value) Calculate the zone factor (see the descriptions above): Zone factor = measuring feed rate / A Q input Qq q = Overtravel and stand-off position The programming input and format is the same whether using one or two-touch cycles. The exception is that the Q input, which with two-touch cycles controls the overtravel distance, also controls the stand-off position for the one-touch cycles (see also Acceleration and deceleration allowance on page K-5). NOTE: The Q value represents the allowable measuring range. The actual overtravel and stand-off distance is automatically increased by the acceleration and deceleration distance (see Acceleration and deceleration allowance on page K-5). Measuring move detail One-touch Stand-off position Q Q Q Stand-off and overtravel positions Figure K.1 Measuring move detail Publication No. H-2000-6222 One-touch measuring K-7 One-touch measuring move logic Start IF probe Y fail Y IF short move Y IF probe open Move to stand-off False position trigger move check Measure move IF false Y trigger loop > 4 Store position Return to start IF false trigger END Alarms Publication No. H-2000-6222 K-8 One-touch measuring This page intentionally left blank. Publication No. H-2000-6222 Renishaw plc T +44 (0)1453 524524 New Mills, Wotton-under-Edge, F +44 (0)1453 524901 Gloucestershire, GL12 8JR E uk@renishaw.com United Kingdom www.renishaw.com For worldwide contact details, please visit our main website at www.renishaw.com/contact *H-2000-6222-0A*

该厂商的其他资料

视频
HaasBuilt - EC-1600
HaasBuilt - EC-1600
2019-01-2127
哈斯自动数控机械(上海)有限公司
PDF
车床操作手册2014
车床操作手册2014
2019-01-17129
哈斯自动数控机械(上海)有限公司
PDF
车床操作手册2014
车床操作手册2014
2019-01-1764
哈斯自动数控机械(上海)有限公司
样本库微信小程序

微信扫一扫,手机找样本

© 2024 样本库 京ICP备17018997号-1

想要解决产品营销和销售难题?

不妨试试样本通
了解更多