Smart features
Smart sensing
Monitoring of key components enables predictive
diagnostics and precision control
Smart transmission
Enhanced efficiency and convenience in data transmission with
remote data burning and transmission
Smart control
Flexible power control and self-adjustment guarantees
maximum output of the entire wind farm
Industry-leading adaptability
Environment adaptability
Flexible power control
Maintenance adaptability
Dual circuit design of electrical system enables partial
operation when one circuit is compromised, thus improving MTBF
Construction adaptability
Individual blade assembly to conserve site space
GW155-4.5MW
PMDD Smart Wind Turbine
Please scan QR code
for more information
GW 155-4.5MW
PMDD Smart Wind Turbine
Operating parameters Rated output voltage V 690
Rated power MW 4.5 Brake system
Wind turbine class IEC III B/S Aerodynamic brake
Aerodynamic brake system \
Cut-in wind speed m/s 2.5 via feathering
Rated wind speed m/s 10.8 Generator hydraulic brake
Mechanical brake system \
Cut-out wind speed m/s 26(High wind ride through) (for maintenance)
Design service life Year ≥ 20 Yaw system
-20℃ ~ +45℃ (Extendable to
-30℃ ~ +45℃, Motor-driven/Four-stageType/Design \
Operating temperature ℃ at 0m altitude, de-rating planetary gear reducer
temperature is 40℃ and
cut-out temperature is 45℃ ) Yaw brake \ Hydraulic brake
Control system and lightning protection
-30℃ ~ +50℃ (Extendable to
Survival temperature ℃
-40℃ ~ +50℃ ) Type \ PLC control system
Rotor system
Lightning protection IEC61400/24-2010、
\
Rotor diameter m 155 design standard IEC62305-2010 standards
Swept area m2 18869
Generator Integrated lightning protection
Lightning protection strategy \ system for the turbine
Permanent magnet (GL certification standards)
Type \
synchronous generator
If the average earth resistivity
Rated voltage V 740 Wind turbine ρ ≤ 3000 Ω·m, the power
Ω frequency grounding resistance
ground resistance
Converter R for each Wind Turbine should
be less than 4 Ω
Type \ Full power converter
Tower
Capacitive
Power factor regulation range \
0.9 - inductive 0.9 Type \ Steel tower
Rated output frequency Hz 50/60 Hub height m 95/110/140 (project specific)
1. Generator cooling system
2. Wind sensors
3. Hoist 8 2
4. Yaw system 10 6
5. Nacelle base
6. Nacelle cover
7. Generator stator 11 3
8. Generator rotor 9 7
9. Hub 5 4 1
10. Blade
11. Pitch system